INSTALLATION
TROUBLESHOOTING
USER GUIDE
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
PAGE CONTENTS |
Table of Contents |
---|
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
PHOTO & DESCRIPTION |
Custom made 2 core + Earth cable for connection to Midea FCU connector CN40 to C225 AC unit cable terminal
1️⃣ X Connection: Red is the X connection to the C225 AC unit cable terminal
2️⃣ Y Connection: White is the Y connection to the C225 AC unit cable terminal
3️⃣ Cable: The cable is 1.5 meters long with a protective sheath
4️⃣ CN40: Midea FCU proprietary connector see pin out diagram to confirm X and Y connectionsThe CDAK6 is a double adaptor to drive two damper motors to be driven from a single zone port on the C225 or CEXT modules
1️⃣ Connector: This is an RJ11 or RJ12 jack for which connects into the C225 or CEXT damper ports
2️⃣ Fly lead
3️⃣ Double adaptor: This converts from 1 to 2 ports
4️⃣ Damper motor ports: Connect damper cables into these ports. Ensure the same type is used as the damper port and C225 ports (RJ11 or RJ12)
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
SPECIFICATIONS |
Model numbers | CDAK, CDAK6 |
Power supply | From C225 (damper motor port) |
Casing material | Fire retardant ABS plastic |
Operating Temperature | Up to 65oC |
Suitable connectors | CDAK - RJ11 CDAK6 - RJ12 or RJ11 |
O/A Dimensions (excludes fly lead) | Height 38 mm Width 26 mm Length 64 mm |
Weight | 16 g |