INSTALLATION
1️⃣ Remove the smart plug from the packaging
2️⃣ Plug the smart plug into the wall outlet (One at at time)
3️⃣ Switch the power at the wall outlet on
...
PHOTO & DESCRIPTION |
1️⃣ Circuit being monitored: Active cable
2️⃣ CPMCT: iZone current transformer (CT)
3️⃣ Connector: The CT has a male connector and the power monitoring device has a female connected. Unused female connectors have a weather proof plug. The connectors are used to enable the CT to be installed on a circuit inside a switch board or cabinet while the CPMD is installed out side the switchboard
4️⃣ CPMD: iZone power monitoring device
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
SPECIFICATIONS |
Model numbers | CPMK | |
Certification | C Tick N29007 | |
Power supply | 2 x AA batteries | |
Connection | To be installed by a licenced electrician in accordance with AS/NZ 3000:2007 Electrical installations. | |
Measured current range | 20mA to 80Amp | |
Sensitivity | This device will measure in 1 Watt increments down to 5 Watts | |
Maximum connected load permitted | 5 Amp | |
Accuracy | This device is for monitoring only and is not recommended for calculation of actual power consumption. Accuracy can be up to 98% over an extended period but will vary as the batteries age and the "Power Factor" fluctuates at the site. | |
Control frequency | 433 MHz | |
Operating Temperature | -20oC to +50oC | |
Environment | Suitable for indoor or outdoor use. The CPMD must not be located inside a steel switch board or cabinet as this will prevent RF transmission of the data. | |
Limitations | Each CPMD can be fitted with up to 3 CPMCT and monitor 3 single phase circuits or one three phase circuit. A maximum of 5 CPMD devices can be installed on a single system. (15 x single phase circuits) | |
Requirements | An iZone bridge (COCB) and iZone World Wide account is required to view the iZone power monitoring system | |
Model number Height mm Width mm Depth mm Cable Diameter mm Weight g | CPMD 100 70 30 N/A 205 | CPMCT 46 30 30 15.5 90 |
Panel | ||||||
---|---|---|---|---|---|---|
|
...
PAIRING
1️⃣ Pair the iZone smart plug to the iZone Bridge by pressing the pair button on the smart plug and on the screen simultaneously
...
INSTALLATION |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
The installation of the iZone power monitoring current transducers (CT's) must be undertaken by an electrician in accordance with AS/NZ 3000:2007 Electrical installations |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
SETUP THE CMPD |
3️⃣ At the same time press the Pair button on the touchscreen or the App
4️⃣ The blue LED will flash rapidly to indicate this device is paring to the system
5️⃣ The screen will confirm that this device is configured and its allocated Device number
6️⃣ Replace the back cover
Panel | ||||||
---|---|---|---|---|---|---|
|
...
CONFIGURE
1️⃣ Name your smart plug on the screen or app
...
FIT THE CT SENSOR CLAMPS |
1️⃣ You need to ensure the CT sensor clamps are installed on the correct cable to receive the correct readings
These options are a guide only and you should consult your electrician to ensure the location of the CT sensors is correct
Panel | ||
---|---|---|
|
...
|
...
|
...
USE YOUR SMART PLUG
1️⃣ Plug the appliance to be controlled into the iZone smart plug
2️⃣ Control your appliance via the touch screen , smart phone or tablet , or iZone wireless switch or the on / off button on the iZone smart plug
...
| |
It may be necessary for the electrician to modify the wiring in your switchboard to achieve the correct result for your particular installation |
2️⃣ Pull the clip on the CT clamp and open it
3️⃣ Place the cable in the CT and close it. Make sure the clip on the CT clicks closed and locks in place
4️⃣ Drill a hole in the side or bottom of the switchboard. It should be large enough to accommodate all the CT cables you are installing plus a rubber grommet
5️⃣ Install a suitable rubber grommet into the hole (Not supplied)
6️⃣ Pass the connectors through the hole
7️⃣ If the switchboard is located outdoors, ensure the penetration into the switchboard is waterproof
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
WIRING DIAGRAMS |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
SINGLE PHASE INSTALLATION WITH SOLAR |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
THREE PHASE INSTALLATION WITH SOLAR |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
SINGLE PHASE INSTALLATION MONITORING TOTAL POWER USED, AIRCON AND LIGHTING |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
TWO PHASE INSTALLATION MONITORING TOTAL POWER USED AND AIRCON |