Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Panel
panelIconIdatlassian-info
panelIcon:info:
bgColor#B3D4FF

Carrier Compatibility: SHDV series inverter ducted, single phase units only

SERIES & kW

INDOOR

OUTDOOR

HIGH STATIC / 9kw - 16.5kw

42SHDV###

38SHDV###

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

Current Firmware Version - 1.0

SERIES & kW

INDOOR

OUTDOOR

HIGH STATIC / 9kw - 16.5kw

42SHDV###

38SHDV###

Panel
panelIconIdatlassian-check_mark
panelIcon:check_mark:
bgColor#ABF5D1

Can use RA, Zones, Master and RF as controlling sensor

Panel
panelIconIdatlassian-warning
panelIcon:warning:
bgColor#FFF0B3

Polarity is critical see below, for correct connection

  • Connect a shielded, 2 core, twisted pair control cable from the  C225 / C325A to the  X / Y in the fan coil unit. This cable and connector is supplied by iZone - CACUCM15

1️⃣ Indoor fan coil unit PCB

2️⃣ CN40: Connect to X and Y

3️⃣ C225 AC unit connector: Connect AC unit cable from fan coil to C225 as indicated

4️⃣ Polarity is critical: Make sure it is wired in accordance with these instructions on both the CN40 connector on the fan coil PCB and the C225 cable connector

5️⃣ Cable from CN40: Ensure the cable is shielded, 2 core, twisted pair. This cable is pre-terminated suitable for CN40 connector and is supplied by iZone