PAGE CONTENTS

Table of Contents
minLevel1
maxLevel7

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

PHOTO & DESCRIPTION

1️⃣ Circuit being monitored: Active cable

2️⃣ CPMCT: iZone current transformer (CT)

3️⃣ Connector: The CT has a mail male connector and the power monitoring device has a female connected. Unused female connectors have a weather proof plug. The connectors are used to enable the CT to be installed on a circuit inside a switch board or cabinet while the CPMD is installed out side the switchboard

4️⃣ CPMD: iZone power monitoring device

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

SPECIFICATIONS

Model numbers

CPMK

Certification

C Tick  N29007  

Power supply

2 x AA batteries

Connection

To be installed by a licenced  electrician in accordance with AS/NZ 3000:2007 Electrical installations.

Measured current range

20mA to 80Amp

Sensitivity

This device will measure in 1 Watt  increments down to 5 Watts

Maximum connected load permitted

5 Amp

Accuracy

This device is for monitoring only and is not recommended for calculation of actual power consumption. Accuracy can be up to 98% over an extended period but will vary as the  batteries age and the "Power Factor" fluctuates at the site.

Control frequency

433 MHz

Operating Temperature

-20oC to +50oC

Environment

Suitable for indoor or outdoor use.  The CPMD must not be located inside a steel switch board or cabinet as this will prevent RF transmission of the data.

Limitations

Each CPMD can be fitted with up to 3 CPMCT and monitor 3 single phase circuits or one three phase circuit.

A maximum of 5 CPMD devices can be installed on a single system.  (15 x single phase circuits)

Requirements

An iZone bridge (COCB) and iZone World Wide account is required to view the iZone power monitoring system

Model number

Height mm

Width mm

Depth mm

Cable Diameter mm

Weight g

CPMD

100

70

30

N/A

205

CPMCT

46

30

30

15.5

90

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

INSTALLATION

Panel
panelIconIdatlassian-warning
panelIcon:warning:
bgColor#FFF0B3

The installation of the iZone power monitoring current transducers (CT's) must be undertaken by an electrician in accordance with AS/NZ 3000:2007 Electrical installations

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

SETUP THE CMPD

3️⃣ At the same time press the Pair button on the touchscreen or the App

4️⃣ The blue LED will flash rapidly to indicate this device is paring to the system

5️⃣ The screen will confirm that this device is configured and its allocated Device number

6️⃣ Replace the back cover

Image RemovedImage Added

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

FIT THE CT SENSOR CLAMPS

1️⃣ You need to ensure the CT sensor clamps are installed on the correct cable to receive the correct readings

These options are a guide only and you should consult your electrician to ensure the location of the CT sensors is correct

Panel
panelIconIdatlassian-warning
panelIcon:warning:
bgColor#FFF0B3

It may be necessary for the electrician to modify the wiring in your switchboard to achieve the correct result for your particular installation

2️⃣ Pull the clip on the CT clamp and open it

3️⃣ Place the cable in the CT and close it. Make sure the clip on the CT clicks closed and locks in place

4️⃣ Drill a hole in the side or bottom of the switchboard. It should be large enough to accommodate all the CT cables you are installing plus a rubber grommet

5️⃣ Install a suitable rubber grommet into the hole (Not supplied)

6️⃣ Pass the connectors through the hole

7️⃣ If the switchboard is located outdoors, ensure the penetration into the switchboard is waterproof

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

WIRING DIAGRAMS

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

SINGLE PHASE INSTALLATION WITH SOLAR

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

THREE PHASE INSTALLATION WITH SOLAR

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

SINGLE PHASE INSTALLATION MONITORING TOTAL POWER USED, AIRCON AND LIGHTING

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

TWO PHASE INSTALLATION MONITORING TOTAL POWER USED AND AIRCON