Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZone Compatibility: |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Current Firmware Version - 1.3 |
SERIES & kW | INDOOR | OUTDOOR |
Single Phase - 7kw / 17kw | AD###-I | AD###-O |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Can use RA, Zones, Master or RF as controlling sensor |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Unit static pressure can be set in the iZone configuration |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Polarity is critical see below, for correct connection |
Connect a 2 core + earth, twisted pair control cable from the C225 / C325i to the X / Y in the fan coil unit. This cable is supplied by iZone - CACUCM15
1️⃣ Indoor fan coil unit PCB
2️⃣ CN40: Connect to X and Y
3️⃣ C225 AC unit connector: Connect AC unit cable from fan coil to C225 as indicated
4️⃣ Polarity is critical: Make sure it is wired in accordance with these instructions on both the CN40 connector on the fan coil PCB and the C225 cable connector
5️⃣ Cable from CN40: Ensure the cable is shielded, 2 core, twisted pair. This cable is pre-terminated suitable for CN40 connector and is supplied by iZone