Kaden Compatibility:

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

Current Firmware Version - 1.3

SERIES & kW

INDOOR

OUTDOOR

Single Phase - 7kw / 17kw

KD###

 

Panel
panelIconIdatlassian-check_mark
panelIcon:check_mark:
bgColor#ABF5D1

Can use RA, Zones, Master or RF as controlling sensor

Panel
panelIconIdatlassian-warning
panelIcon:warning:
bgColor#FFF0B3

Polarity is critical see below, for correct connection

  • Connect a 2 core + earth, twisted pair control cable from the  C225 / C325KAD to the  X / Y in the fan coil unit. This cable is supplied by iZone - CACUCM15

Image RemovedCN40.jpgImage Added

1️⃣ Indoor fan coil unit PCB

2️⃣ CN40: Connect to X and Y

3️⃣ C225 AC unit connector: Connect AC unit cable from fan coil to C225 as indicated

4️⃣ Polarity is critical: Make sure it is wired in accordance with these instructions on both the CN40 connector on the fan coil PCB and the C225 cable connector

5️⃣ Cable from CN40: Ensure the cable is shielded, 2 core, twisted pair. This cable is pre-terminated suitable for CN40 connector and is supplied by iZone