C325H - Emerald

C325H - Emerald

Emerald Compatibility

Confirmed compatible with C325H v2.4. Uses the same control method and wiring as Hitachi (TB2: A-B). Works as a Hitachi AC unit for iZone integration.

Current Firmware Version - 2.4

Supported Models

SERIES & kW

INDOOR

OUTDOOR

SERIES & kW

INDOOR

OUTDOOR

R32 High/Medium Static Ducted 16 kW

ACR160D

ACR160U

R32 High/Medium Static Ducted 20 kW

ACV200D

ACV200U

Notes: Emerald ducted units listed above were manufactured by Hitachi per product owner discussion. Treat selection and wiring as per Hitachi C325H.

Sensor Options

  • Can use RA, Zones, Master or RF as the controlling sensor.

  • Polarity is not critical on A/B communication pair.

Connection and Wiring

  • Connect a shielded, 2-core, twisted pair control cable from the C225 / C325H to the fan coil control terminals TB2: A and B, with earth/shield bonded at the fan coil end.

  • Do not apply any voltage to this communication cable.

  • Wiring is identical to Hitachi C325H. Refer to: C325H - Hitachi

photo_2024-08-07_15-42-49.jpg