C325TC - TCL
TCL Compatibility:
Current Firmware Version - 1.0
Minimum firmware requirements
C225 v3.74
COCBH v4.31
Can do Return Air, Zones, Master or RF as controlling sensor.
Cannot use TCL wall controller as secondary wall controller.
CODE | SENSOR TYPE | CONNECTION |
|---|---|---|
C325TC v1.0 | RA, Zones, Master, RF | P2/P3 - Polarity Critical |
SERIES & kW | INDOOR | OUTDOOR |
R32 8.5KW | TCD71D1HWH-DVI | TCD71D1HWH-DVO |
R32 10.0KW | TCD85D1HWH-DVI | TCD85D1HWH-DVO |
R32 12.5KW | TCD100D1HWH-DVI | TCD100D1HWH-DVO |
R32 14KW | TCD125D1HWH-DVI | TCD125D1HWH-DVO |
R32 16KW | TCD140D1HWH-DVI | TCD140D1HWH-DVO |
Polarity IS critical see the wiring diagram and photo, for correct connection
Connect TCL P2 and P3 to IZONE interface
Use Shielded, 2 core, twisted pair control cable: Polarity is critical.
Wiring diagram.
C325TC module