C325L2: LG
LG Compatibility: AWY-7G6 Series
Can use RA, Zones, Master or RF as controlling sensor
Polarity is not critical
Connect the LG supplied cable from the fan coil unit to the iZone C225 module Only use the black and yellow cables
Connect black and yellow wires only: Use the connector supplied with the LG unit to connect from the fan coil to the iZone C225. Only connect the black and yellow cables to the C225. Polarity is not critical
LG control cable: Connect black and yellow cables only.
Red cable not used: Red cable is not required for iZone connection
C325M2: MITSUBISHI ELECTRIC
Mitsubishi Electric Compatibility:
PE-M##GAA
New MR Slim series (Must be C325M2)
C320M & C325M have been superseded by C325M2
Can use RA, Zones, Master or RF as controlling sensor
Polarity is not critical
TakeĀ the Remote Controller (A / B) control wire from the fan coil unit and connect it to the AC Unit Control Cable on theĀ C225 / C325M2
Connect to A / B terminals: Connect wires to to A and B terminals. Polarity is not critical
Mitsubishi Electric FCU PCB
C225: iZone C225 module with C325M2 AC unit module connected
Shielded, 2 Core, twisted pair: This cable is not provided by iZone