INSTALLATION

1️⃣ Voltage Free Contact Module: After pairing the voltage free contact module (CVFC) must be changed in the configuration area to a “Garage Door”

2️⃣ Mains Power: 240V mains power

3️⃣ Voltage free terminals: Voltage free terminals in the existing garage door controller

4️⃣ Existing garage door GPO

5️⃣ Reed Switch: Pair and group the reed switch to the system and mount onto door / frame

6️⃣ Existing garage door controller

After installation and reconfiguration, test the operation of the door several times to ensure correct operation. If the door does not operate correctly change the pulse length, in the configuration then re-test

CONFIGURATION

Install the wiring to the garage door as indicated above

1️⃣ Name smart plug:

Rename your smart plug to something more appropriate

2️⃣ Set up Group:

Set up a group for the garage door controller and associated reed switch

3️⃣ Adjust pulse length:

Test you garage door and adjust the pulse length to ensure the door operates correctly

4️⃣ Press to change to garage door control:

Press to change the operation of the smart plug to a garage door

5️⃣ Reed switch in group:

Pair the Reed switch to be used to indicate if the garage door is open or closed

Set the group for the Reed Switch to the same group as the Garage Door controller

CONFIGURATION QUICK GUIDE

1️⃣ Pair the smart plug and then create a name (Garage Door)

2️⃣ Pair the Reed switch for the Garage Door and then group the Garage Door Smart Plug and the Reed Switch to same group number

3️⃣ Go to the detail section (Click on the pencil icon) for the Garage Door Smart plug and change it from a standard Smart Plug to a Garage Door controller

4️⃣ Test and adjust Pulse length as required