Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
PAGE CONTENTS |
Table of Contents |
---|
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
PHOTO & DESCRIPTION |
1️⃣ Smart plug: Smart plugs can be used for remote control of 240V devices powered from a standard AU general purpose outlet
2️⃣ Australian plug: AU Plug
3️⃣ Pair button: The pair button is located on the side of the iZone smart plug. Press and hold the pair button while pressing the pair button on the App or on the iZone screen. The LED will flash red rapidly to indicate it is paring to the system
4️⃣ Manual On/Off button: The smart plug can be controlled manually from the on off button. When on the LED behind the button will be blue and when off it will be red Circuit being monitored: Active cable
2️⃣ CPMCT: iZone current transformer (CT)
3️⃣ Connector: The CT has a mail connector and the power monitoring device has a female connected. Unused female connectors have a weather proof plug. The connectors are used to enable the CT to be installed on a circuit inside a switch board or cabinet while the CPMD is installed out side the switchboard
4️⃣ CPMD: iZone power monitoring device
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
SPECIFICATIONS |
Model numbers |
CPMK | |
Certification |
C Tick N29007 |
| |
Power supply |
Input: 220 - 240VAC 50Hz
Power consumption
Maximum 1.9 Watts switched on (no load connected)
Minimum 0.6 Watts switched off2 x AA batteries | ||
Connection | To be installed by a licenced electrician in accordance with AS/NZ 3000:2007 Electrical installations. | |
Measured current range | 20mA to 80Amp | |
Sensitivity | This device will measure in 1 Watt increments down to 5 Watts | |
Maximum connected load permitted |
5 Amp |
Connection
Accuracy | This device is for monitoring only and is not recommended for calculation of actual power consumption. Accuracy can be up to 98% over an extended period but will vary as the batteries age and the "Power Factor" fluctuates at the site. | |
Control frequency | 433 MHz | |
Operating Temperature | - |
20oC to + |
50oC | ||
Environment | Suitable for indoor |
or outdoor use. The CPMD must not be located inside a steel switch board or cabinet as this will prevent RF transmission of the data. | ||
Limitations | Each CPMD can be fitted with up to 3 CPMCT and monitor 3 single phase circuits or one three phase circuit. A maximum of 5 CPMD devices can be installed on a single system. (15 x single phase circuits) | |
Requirements | An iZone bridge (COCB) |
Size & Weight
and iZone World Wide account is required to view the iZone power monitoring system | |
Model number Height mm Width |
mm Depth |