Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

iZone has designed interface boards for most major Air Conditioning brands

...

CODE

SENSOR TYPE

CONNECTION

C325F2 v1.10

RA, Zones, Master, RF

SERIES & kW

INDOOR

OUTDOOR

ARTG Series Wiring: Connect AC control cable to 2 and 3 - Polarity IS Critical

High Static Single Phase - Compact Outdoor

ARTG30LHTA

ARTG36LHTA

ARTG45LHTA

High Static Single Phase

ARTG30LHTA

ARTG36LHTA

ARTG45LHTA

ARTG54LHTC

High Static Infinity Range - Single Phase ONLY

ARTG45LDTA (single phase)

ARTG54LDTA (single phase)

ARTG60LDTA (single phase)

High Static Three Phase

ARTC72LATU

ARTC90LATU

ARTH Series Wiring: Connect AC control cable to Y2-Y3 and SW1 dip switch ON - Polarity IS Critical

High Static Single Phase

ARTH60KHTA ( Single Phase )

Standard Range

ARTH54KHTA (Single phase)

High Efficiency

ARTH60KHTB (Single phase)

...

Panel
panelIconIdatlassian-warning
panelIcon:warning:
bgColor#FFF0B3

Gree are using the same model numbers for their new R32 Gas type units

CODE

SENSOR TYPE

CONNECTION

C325G v1.3

RA Only

CN1 / Polarity Critical

Requires proprietary controller

SERIES & kW

INDOOR

OUTDOOR

Inverter ducted, single phase units only R410A gas type only

GUD###PHS/B-S

GUD###W/Nh B-S

NOTES

INDOOR

OUTDOOR

C325G2

GUD50PS/B-S

GUD50W/NhB-S

RA, Zones, Master, RF

GUD71PHS/B-S

GUD71W/NhB-S

R32 Gas type Only

GUD100PHS/B-S

GUD100W/NhB-S

GUD125PHS/B-S

GUD125W/NhB-S

GUD140PHS/B-S

GUD140W/NhB-S

GUD160PHS/B-S

GUD160W/NhB-S

...