C325F2 - Fujitsu
Fujitsu Compatibility:
Current Firmware Version - v1.11
Can use RA, Zones, Master and RF as controlling sensor with v1.11 AC unit module
Polarity is critical for both ARTG and ARTH series wiring to iZone C225.
R410 Gas Type - ARTG Series
R410 Gas Type | INDOOR | OUTDOOR |
High Static Single Phase - Compact Outdoor | ARTG30LHTA ARTG36LHTA ARTG45LHTA ARTG54LHTC | AOTG30LATL AOTG36LATL AOTG45LATL AOTG54LCTL |
High Static Infinity Range - Single Phase ONLY | ARTG45LDTA (single phase) ARTG54LDTA (single phase) ARTG60LDTA (single phase) | AOTG45LBTA AOTG54LBTA AOTG60LBTA |
High Static Three Phase | ARTC72LATU ARTC90LATU | AOTA72LALT AOTA90LALT |
iZone C225 module: Ensure the correct C325 module is connected for the AC unit make it is controlling
AC unit control cable 2 / 3: Connect the AC unit control cable to 2 and 3 on the Fujitsu indoor board. Polarity is critical
Shielded cable: Shielded, 2 core, twisted pair cable must be used and is not supplied by iZone
Do NOT use the terminal 1 (12V) when connecting to an iZone system
R32 Gas Type - ARTH Series
R32 Gas Type | INDOOR | OUTDOOR |
Mid Static Slimline | ARTH18KMTAP | AOTH18KBTA |
Mid Static Slimline | ARTH24KMTAP | AOTH24KBTA |
Mid Static Slimline | ARTH30KMTAP | AOTH30KBTA |
Mid Static Slimline | ARTH36KMTAP | AOTH36KBTA |
Mid Static Slimline | ARTH45KMTAP | AOTH45KBTA |
Mid Static Slimline | ARTH54KMTAP | AOTH54KBTA |
Mid Static Slimline High Performance | ARTH24KMTAP | AOTH24KCTA |
Mid Static Slimline High Performance | ARTH30KMTAP | AOTH30KCTA |
High Static Single Phase High Performance | ARTH30KHTA | AOTH30KCTA |
High Static Single Phase High Performance | ARTH36KHTA | AOTH36KCTA |
High Static Single Phase High Performance | ARTH45KHTA | AOTH45KCTA |
High Static Single Phase High Performance | ARTH54KHTA | AOTH54KCTA |
High Static Single Phase High Performance | ARTH60KHTB | AOTH60KCTA |
High Static Single Phase | ARTH24KHTA | AOTH24KBTA |
High Static Single Phase | ARTH30KHTA | AOTH30KBTA |
High Static Single Phase | ARTH36KHTA | AOTH36KBTA |
High Static Single Phase | ARTH45KHTA | AOTH45KBTA |
High Static Single Phase | ARTH54KHTA | AOTH54KBTA |
High Static Single Phase | ARTH60KHTA | AOTH60KBTA |
High Static Three Phase | ARTH36KHTA | AOTH36KRTA |
High Static Three Phase | ARTH45KHTA | AOTH45KRTA |
High Static Three Phase | ARTH54KHTA | AOTH54KRTA |
High Static Three Phase | ARTH60KHTA | AOTH60KRTA |
iZone C225 module: Ensure the correct C325 module is connected for the AC unit make it is controlling
AC unit Control Cable Y2 / Y3: Connect the AC unit control cable from Y2 / Y3 connection on Fujitsu indoor board to iZone CPU. Polarity is critical
Shielded cable: Shielded, 2 core, twisted pair cable must be used and is not supplied by iZone
Do NOT use the terminal Y1 (12V) when connecting to an iZone system
Set this DIP switch (SW1) into the UP position - see photos below