Mitsubishi Electric Compatibility:

Current Firmware Version - 1.3

Release notes - AC gateways

Minimum firmware requirements for 4-fanspeed:

  • C225: v3.69

  • COCBH: v4.29

  • C325M2: V1.2

Minimum firmware requirements for VRF (Multi-City):

  • C225: v3.72

  • C325M2: v1.3

  • CVRFH: v1.1

  • COCBH: v4.29

  • NOVA: v1.15

Can use RA, Zones, Master or RF as controlling sensor

R410 Gas Type

INDOOR

OUTDOOR

AC UNIT MODULE

10kw - 14kw

PEA-M##GAA

 

C325M2

10kw - 14kw

PEA-M##HAA

 

10kw - 14kw

PEA-M##JAA

 

20kW

PEA-RP200WJA

PUZ-RP200YKA

C325M

(contact salesdesk@izone.com.au)

25kW

PEA-RP250WHA

PUZ-RP250YKM

R32 Gas Type

 

PEAM160HAAYKIT

PEA-M160HAA

PUZ-ZM160YKA-A.TH

C325M2

PEAM180LAAYKIT

PEA-M180LAA.TH

PUZ-ZM180YKA-A.TH

PEAM200/250YKIT

PEA-M200/250LAA.TH

PUZ-ZM200/250YKA-A.TH

R32 VRF units

Low Noise Ceiling Concealed

PEFY-P VMR-E-L/R     

 

PUMY-P Series

PUMY-SP Series

 

C325M2 (min firmware version 1.3)

See CVRFH host module page

Low Static Pressure Ceiling Concealed

PEFY-P VMS1(L)-E      

 

Medium Static Pressure Ceiling Concealed

PEFY-P-VMA(L)-E4     

 

Compact Depth Ceiling Concealed

PEFY-P VMX(L)-E(1)   

 

High Static Pressure Ceiling Concealed

PEFY-P-VMHS-E         

 

Fresh Air Intake Ceiling Concealed

PEFY-P VMHS-E-F      

 

Wall Mounted

PKFY-P-VLM-E           

PKFY-P-VKM-E         

Polarity is not critical

  • Take  the Remote Controller (A / B) control wire from the fan coil unit and connect it to the AC Unit Control Cable on the  C225 / C325M2

Please make sure to check the DIP SWITCH settings on the indoor unit board for NEW R32 Gas Type ME MODELS. DIP switch 8 on switch SW5 needs to be in the off position for both the old and the new modules to work.

original-D8492919-571D-418C-9E5F-9803EEB4EEFE.jpeg

(your indoor PCB might look differently)

A hard reset must be performed after you have changed the dip switch settings

 

Connect to A / B terminals: Connect wires to to A and B terminals. Polarity is not critical

Mitsubishi Electric FCU PCB

C225: iZone C225 module with C325M2 AC unit module connected

Shielded, 2 Core, twisted pair: This cable is not provided by iZone

R32 VRF units

C325M2 may cycle if zone sensor location does not match AC unit configuration.

To switch between zone control with temperature sensors and return air control, please refer to ME fan coil unit instructions to locate control board switch. Zone sensor location switch settings may differ from example below.

Remote to Return Air Control Example.jpg
Example of ME dipswitch to switch set zone control temperature sensors mode.