C325R - Rinnai

C325R - Rinnai

Rinnai Compatibility:

Current Firmware Version - 1.0

SERIES & kW

INDOOR

OUTDOOR

DINLR XX Series only

 

 

Can use RA, Zones, Master or RF as controlling sensor

Polarity is critical see below, for correct connection

For CN40 connection

For connection of older R410A fan coil units below:

Compatible Indoor Models

DINLR07Z72

DINLR10Z721

DINLR14Z72

DINLR17Z72

Compatible Indoor Models

DINLR07Z72

DINLR10Z721

DINLR14Z72

DINLR17Z72

  • Connect a 2 core + earth, twisted pair control cable from the  C225 / C325R to the CN40/CN9/CNXYE port on the fan coil unit. This cable is supplied by iZone - CACUCM15

 

CN40.jpg
Screenshot 2024-02-15 155548.jpg

 

The new Rinnai indoor units may have either of two connections: CN9 and CNXYE.

For CN9 connection

Connection for Three phase systems 20+kW.

Compatible Indoor Models

DINLR20Z7

DINLR24Z7

Compatible Indoor Models

DINLR20Z7

DINLR24Z7

 

CN9.jpg

 

Screenshot 2024-02-15 155316.jpg

For CNXYE Connection

Single phase R32 models 7-18 kW.

Compatible Indoor Models

DINLR07B1

DINLR09B1

DINLR11B1

DINLR13B1

DINLR15B1

DINLR18B1

Compatible Indoor Models

DINLR07B1

DINLR09B1

DINLR11B1

DINLR13B1

DINLR15B1

DINLR18B1

  • Connect a 2 core + earth, twisted pair control cable fro

CNXYE.jpg
7b50a67b-87fe-437a-a2bf-4828a1e50db1.jpg

Indoor fan coil unit PCB

CN40: Connect to X and Y

C225 AC unit connector: Connect AC unit cable from fan coil to C225 as indicated

Polarity is critical: Make sure it is wired in accordance with these instructions on both the CN40 /CN9/CNXYE connector on the fan coil PCB and the C225 cable connector

Cable from CN40: Ensure the cable is shielded, 2 core, twisted pair. This cable is pre-terminated suitable for CN40 connector and is supplied by iZone

 

Resetting the Unit Addressing on Rinnai 20Kw+ units

When a Rinnai AC unit controller is used to do a test run, to put the iZone control system back on and operate the AC, unit addressing needs to be reset. Below is the procedure on how to do it.

  • First, make sure to cut the power to the indoor and outdoor unit both.

Off.png

 

  • Clear the indoor addresses by adjusting the S6 dip switch on OUTDOOR UNIT BOARD according to the photo:

    Dip switch ON-OFF.png

     

image-20240823-022015.png
  • Wait for 5 minutes, then turn both indoor and outdoor units back on.

On.png
  • Please wait another 5 minutes and turn it off again.

 

Off.png
  • Next, switch the unit to automatic addressing as shown below:

     

 

Dip switch ON-ON.png

 

 

IMG_3025.PNG

 

  • Now please power to the both indoor and outdoor back up

  • Connect iZone system back to the indoor unit and wait for 5 minutes.

  • You can run your AC by iZone system now.