iZone offers a wide range of different AC control systems, below is a description of each type of system

Panel
panelIconIdatlassian-info
panelIcon:info:
bgColor#B3D4FF

PAGE CONTENTS

Table of Contents

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2
iZONE

110 SERIES

110 is a basic low cost zone only control system which is suitable for switching zones Open and Closed

A summary of the features iZone 110 offers are listed below:

...

Panel
panelIconIdatlassian-warning
panelIcon:warning:
bgColor#FFF0B3

It is not possible to upgrade an iZone 110 system to the iZone 400 series however you will be able to use the iZone damper motors, zone cables, transformer and CAT 5E cables

WIRING LAYOUT

...

INSTALLATION INSTRUCTIONS

1️⃣ The C110MC can be installed on top of the indoor fan coil unit

2️⃣ Do not run the blue network cables alongside 240 Volt wiring

3️⃣ When installing network cables down wall cavities or chasing network cables into walls, tape up and protect the RJ45 connector to avoid damage to the connectors

4️⃣ Always install zones in consecutive ports starting at Zone 1. The back of the C110MC is marked with the zone port numbers

5️⃣ Do not directly hardwire the CT24ACE into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 110 system is required

6️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown

7️⃣ Connect the Wall controller(s) (C110WC) to the C110WC ports using the RJ45 cables

8️⃣ Only connect the power supply to the CT24AC port after all components have been connected

9️⃣ Initialise the system

1️⃣ 0️⃣ Configure the system

SYSTEM INITIALISATION

All new or modified systems must be initialised prior to system configuration

To initialise the system press the button on the underside of any wall controller. This button is recessed so you will need to use a pen to press the button

The time to initialise the system will vary depending on the number of motors connected

The system will also initialise when power is restored after a power failure

...

 

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2
iZONE

150 SERIES

- ZONE ONLY

iZone 150 Zone only and 155 is a basic low cost zone only control system which is suitable for switching zones Open and Closed

A summary of the features iZone 150 Zone only offers are listed below:

  • Up to 6 zones available

  • Zones air quantities can be balanced from the CEPC controller (no need for separate manual balancing dampers)

  • Zone airflows can be adjusted by the end user from the CEPC controller

  • Multiple CEPC controllers can be added

  • Zone temperatures can be controlled from CEPC if iZone sensors are fitted to the system

  • Label zone names from a standard library of names built into the controller

  • Electronic constants can be set-up

Panel
Panel
panelIconIdatlassian-warning
panelIcon:warning:
bgColor#FFF0B3

There is no facility to control the zones via Wi-Fi

panelIconIdatlassian-info
panelIcon:info:
bgColor#B3D4FF

The an An AC unit module can be added to the iZone 150 to provide integrated AC unit and zone control

WIRING LAYOUT

...

INSTALLATION INSTRUCTIONS

1️⃣ The C150 can be installed on top of the indoor fan coil unit

2️⃣ Do not run the blue network cables alongside 240 Volt wiring

3️⃣ Always install zones in consecutive ports starting at Zone 1. The front of the C150 is marked with the zone port numbers

4️⃣ Do not directly hard wire the CT24ACM into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 150 system is required

5️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown

6️⃣ Remove the tabs on the CEPC batteries to activate power to the controller

7️⃣ Only connect the power supply to the CT24ACM port after all components have been connected

8️⃣ Initialise the system

9️⃣ Configure the system

INITIALISATION INSTRUCTIONS

All new or modified systems must be initialised prior to system configuration

To initialise the system remove the power from the C150 module, wait 15 seconds and restore power to the C150 module

The time to initialise the system will vary depending on the number of motors connected

The system will also initialise when power is restored after a power failure

Panel
panelIconIdatlassian-check_mark
panelIcon:check_mark:
bgColor#ABF5D1

Add a smart hub to the 150 and it becomes a 155, Now you can control all our other iZone automation products such as lighting, irrigation, garage door control, roller blinds etc

It can also be controlled via the iZone Home App

 

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

iZONE

155 SERIES - ZONE ONLY

iZone 155 is a basic low cost zone only control system which is suitable for switching zones Open and Closed

A summary of the features of the iZone 155 zone only are listed below:

  • Up to 6 zones available

  • Zones air quantities can be balanced from the CEPC controller (no need for separate manual balancing dampers)

  • Zone airflows can be adjusted by the end user from the CEPC controller

  • Multiple CEPC controllers can be added

  • Zone temperatures can be controlled from CEPC if iZone sensors are fitted to the system

  • Label zone names from a standard library of names built into the controller. Customised names can be input via your smart device

  • Electronic constants can be set up

  • WiFi or 5G control of your zones and other smart iZone devices

...

panelIconIdatlassian-info
panelIcon:info:
bgColor#B3D4FF

...

NAKED 400 & 405 SERIES

iZone Naked 400 & 405 is an inexpensive zone controller that uses a wireless controller (CEPC)

The Naked 400 & 405 series is for zone control only and does not integrate with the AC unit. Zones can be temperature controlled by adding iZone sensors and an induct temperature sensor

iZone 400 can be configured as 0-8 zones or 9-14 zones by adding a zone extension

Panel
panelIconIdatlassian-check_mark
panelIcon:check_mark:
bgColor#ABF5D1

Because the iZone 155 is supplied with an iZone Bridge Add a smart hub to the 400 and it becomes a 405, Now you can control all our other iZone automation products such as lighting, irrigation, garage door control, roller blinds etc

It can also be controlled via the iZone Home App

WIRING LAYOUT

...

INSTALLATION INSTRUCTIONS

1️⃣ The C150 can be installed on top of the indoor fan coil unit

2️⃣ Do not run the blue network cables alongside 240 Volt wiring

3️⃣ Always install zones in consecutive ports starting at Zone 1. The front of the C150 is marked with the zone port numbers

4️⃣ Do not directly hard wire the CT24ACM into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 150 system is required

5️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown

6️⃣ Remove the tabs on the CEPC batteries to activate power to the controller

7️⃣ Only connect the power supply to the CT24ACM port after all components have been connected

8️⃣ Initialise the system

9️⃣ Configure the system

1️⃣ 0️⃣ Connect the bridge to the owners modem and connect the bridge power supply. Pair the bridge to the C155 using the pair button on the CEPC screen

INITIALISATION INSTRUCTIONS

All new or modified systems must be initialised prior to system configuration

To initialise the system remove the power from the C150 module, wait 15 seconds and restore power to the C150 module

The time to initialise the system will vary depending on the number of motors connected

The system will also initialise when power is restored after a power failure

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

iZONE NAKED 410 & 415 SERIES

iZone Naked 410 & 415 is an inexpensive integrated AC unit and zone controller that utilizes the end user's own smartphone or tablet to control the zones via the iZone App

The CEPC, if used, is provided primarily for the commissioning and set-up of the AC system by the installers and as a backup in the event of Wi-Fi failing

Zones can be temperature controlled by adding iZone sensors and an induct temperature sensor

The Naked 410 & 415 series is for zone and AC unit control

iZone 410 & 415 can be configured as 0-8 zones or 9-14 zones by adding a zone extension

Panel
panelIconIdatlassian-check_mark
panelIcon:check_mark:
bgColor#ABF5D1

Add a smart hub to the 410 and it becomes a 415, Now you can control all our other iZone automation products such as lighting, irrigation, garage door control, roller blinds etc

It can also be controlled via the iZone Home App

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

iZONE

150 SERIES - INTERGRATED AC UNIT & ZONE CONTROL

iZone 155 is a low cost integrated AC control system which is suitable for controlling zones and complete AC unit control as well as full smart home control via a phone or tablet

A summary of the features iZone 155 offers are listed below:

...

Up to 6 zones available

...

Zones air quantities can be balanced from the CEPC controller (no need for separate manual balancing dampers)

...

Zone airflows can be adjusted by the end user from the CEPC controller

...

Multiple CEPC controllers can be added

...

Zone temperatures can be controlled from CEPC if iZone sensors are fitted to the system

...

Label zone names from a standard library of names built into the controller

...

Electronic constants can be setup

...

NAKED 420 & 425 SERIES

iZone 420 & 425 is an integrated air conditioning unit and zone controller that uses a Nano touch screen (CCTSS#) for the graphic user interface

Zones can be temperature controlled by adding iZone sensors and an induct temperature sensor

The iZone 420 & 425 series is for zone and AC unit control

iZone 420 & 425 can be configured as 0-8 zones or 9-14 zones by adding a zone extension

Panel
panelIconIdatlassian-warningcheck_mark
panelIcon:warningcheck_mark:
bgColor#FFF0B3

There is no facility to control the system via Wi-Fi

WIRING LAYOUT

...

INSTALLATION INSTRUCTIONS

1️⃣ The C150 can be installed on top of the indoor fan coil unit

2️⃣ Do not run the blue network cables alongside 240 Volt wiring

3️⃣ Always install zones in consecutive ports starting at Zone 1. The front of the C150 is marked with the zone port numbers

4️⃣ Do not directly hard wire the CT24ACM into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 150 system is required

5️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown

6️⃣ Connect the AC unit control cable to the C150 as per the instructions for your brand of AC unit found here

7️⃣ Remove the tabs on the CEPC batteries to activate power to the controller

8️⃣ Only connect the power supply to the CT24ACM port after all components have been connected

9️⃣ Initialise the system

1️⃣ 0️⃣ Configure the system

INITIALISATION INSTRUCTIONS

All new or modified systems must be initialised prior to system configuration

To initialise the system remove the power from the C150 module, wait 15 seconds and restore power to the C150 module

The time to initialise the system will vary depending on the number of motors connected

The system will also initialise when power is restored after a power failure

#ABF5D1

Add a smart hub to the 420 and it becomes a 425, Now you can control all our other iZone automation products such as lighting, irrigation, garage door control, roller blinds etc

It can also be controlled via the iZone Home App

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

iZONE

155 SERIES - INTERGRATED AC UNIT & ZONE CONTROL

NAKED 430 & 435 SERIES

iZone 155 430 is a low cost integrated AC control system which is suitable for controlling zones and complete AC unit control as well as full smart home control via a phone or tablet

A summary of the features iZone 155 offers are listed below:

...

Up to 6 zones available

...

Zones air quantities can be balanced from the CEPC controller (no need for separate manual balancing dampers)

...

Zone airflows can be adjusted by the end user from the CEPC controller

...

Multiple CEPC controllers can be added

...

Zone temperatures can be controlled from CEPC if iZone sensors are fitted to the system

...

Label zone names from a standard library of names built into the controller

...

Electronic constants can be setup

...

an integrated air conditioning unit and zone controller that uses a Nexus or Nexus+ touch screen (CCTSL# or CCTSL#+) for the graphic user interface

Zones can be temperature controlled by adding iZone sensors and an induct temperature sensor

The iZone 430 & 435 series is for zone and AC unit control

iZone 430 & 435 can be configured as 0-8 zones or 9-14 zones by adding a zone extension

Panel
panelIconIdatlassian-check_mark
panelIcon:check_mark:
bgColor#ABF5D1

Because the iZone 155 is supplied with an iZone Bridge Add a smart hub to the 430 and it becomes a 435, Now you can control all our other iZone automation products such as lighting, irrigation, garage door control, roller blinds etc

It can also be controlled

WIRING LAYOUT

...

INSTALLATION INSTRUCTIONS

1️⃣ The C150 can be installed on top of the indoor fan coil unit

2️⃣ Do not run the blue network cables alongside 240 Volt wiring

3️⃣ Always install zones in consecutive ports starting at Zone 1. The front of the C150 is marked with the zone port numbers

4️⃣ Do not directly hard wire the CT24ACM into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 150 system is required

5️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown

6️⃣ Connect the AC unit control cable to the C150 as per the instructions for your brand of AC unit found here

7️⃣ Remove the tabs on the CEPC batteries to activate power to the controller

8️⃣ Only connect the power supply to the CT24ACM port after all components have been connected

9️⃣ Initialise the system

1️⃣ 0️⃣ Configure the system

1️⃣ 1️⃣ Connect the bridge to the owners modem and connect the bridge power supply. Pair the bridge to the C155 using the pair button on the CEPC screen

INITIALISATION INSTRUCTIONS

All new or modified systems must be initialised prior to system configuration

To initialise the system remove the power from the C150 module, wait 15 seconds and restore power to the C150 module

The time to initialise the system will vary depending on the number of motors connected

...

via the iZone Home App