iZone offers a wide range of different AC control systems, below is a description of each type of system
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
PAGE CONTENTS |
Table of Contents |
---|
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZONE 110 SERIES |
110 is a basic low cost zone only control system which is suitable for switching zones Open and Closed
A summary of the features iZone 110 offers are listed below:
...
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
It is not possible to upgrade an iZone 110 system to the iZone 400 series however you will be able to use the iZone damper motors, zone cables, transformer and CAT 5E cables |
WIRING LAYOUT
...
INSTALLATION INSTRUCTIONS
1️⃣ The C110MC can be installed on top of the indoor fan coil unit
2️⃣ Do not run the blue network cables alongside 240 Volt wiring
3️⃣ When installing network cables down wall cavities or chasing network cables into walls, tape up and protect the RJ45 connector to avoid damage to the connectors
4️⃣ Always install zones in consecutive ports starting at Zone 1. The back of the C110MC is marked with the zone port numbers
5️⃣ Do not directly hardwire the CT24ACE into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 110 system is required
6️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown
7️⃣ Connect the Wall controller(s) (C110WC) to the C110WC ports using the RJ45 cables
8️⃣ Only connect the power supply to the CT24AC port after all components have been connected
9️⃣ Initialise the system
1️⃣ 0️⃣ Configure the system
SYSTEM INITIALISATION
All new or modified systems must be initialised prior to system configuration
To initialise the system press the button on the underside of any wall controller. This button is recessed so you will need to use a pen to press the button
The time to initialise the system will vary depending on the number of motors connected
The system will also initialise when power is restored after a power failure
...
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZONE 150 SERIES- ZONE ONLY |
iZone 150 Zone only and 155 is a basic low cost zone only control system which is suitable for switching zones Open and Closed
A summary of the features iZone 150 Zone only offers are listed below:
Up to 6 zones available
Zones air quantities can be balanced from the CEPC controller (no need for separate manual balancing dampers)
Zone airflows can be adjusted by the end user from the CEPC controller
Multiple CEPC controllers can be added
Zone temperatures can be controlled from CEPC if iZone sensors are fitted to the system
Label zone names from a standard library of names built into the controller
Electronic constants can be set-up
Panel | ||||||
---|---|---|---|---|---|---|
Panel | ||||||
| ||||||
There is no facility to control the zones via Wi-Fi | ||||||
| ||||||
The an An AC unit module can be added to the iZone 150 to provide integrated AC unit and zone control |
WIRING LAYOUT
...
INSTALLATION INSTRUCTIONS
1️⃣ The C150 can be installed on top of the indoor fan coil unit
2️⃣ Do not run the blue network cables alongside 240 Volt wiring
3️⃣ Always install zones in consecutive ports starting at Zone 1. The front of the C150 is marked with the zone port numbers
4️⃣ Do not directly hard wire the CT24ACM into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 150 system is required
5️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown
6️⃣ Remove the tabs on the CEPC batteries to activate power to the controller
7️⃣ Only connect the power supply to the CT24ACM port after all components have been connected
8️⃣ Initialise the system
9️⃣ Configure the system
INITIALISATION INSTRUCTIONS
All new or modified systems must be initialised prior to system configuration
To initialise the system remove the power from the C150 module, wait 15 seconds and restore power to the C150 module
The time to initialise the system will vary depending on the number of motors connected
The system will also initialise when power is restored after a power failure
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Add a smart hub to the 150 and it becomes a 155, Now you can control all our other iZone automation products such as lighting, irrigation, garage door control, roller blinds etc It can also be controlled via the iZone Home App |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZONE155 SERIES - ZONE ONLY |
iZone 155 is a basic low cost zone only control system which is suitable for switching zones Open and Closed
A summary of the features of the iZone 155 zone only are listed below:
Up to 6 zones available
Zones air quantities can be balanced from the CEPC controller (no need for separate manual balancing dampers)
Zone airflows can be adjusted by the end user from the CEPC controller
Multiple CEPC controllers can be added
Zone temperatures can be controlled from CEPC if iZone sensors are fitted to the system
Label zone names from a standard library of names built into the controller. Customised names can be input via your smart device
Electronic constants can be set up
WiFi or 5G control of your zones and other smart iZone devices
...
panelIconId | atlassian-info |
---|---|
panelIcon | :info: |
bgColor | #B3D4FF |
...
NAKED 400 & 405 SERIES |
iZone Naked 400 & 405 is an inexpensive zone controller that uses a wireless controller (CEPC)
The Naked 400 & 405 series is for zone control only and does not integrate with the AC unit. Zones can be temperature controlled by adding iZone sensors and an induct temperature sensor
iZone 400 can be configured as 0-8 zones or 9-14 zones by adding a zone extension
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Because the iZone 155 is supplied with an iZone Bridge Add a smart hub to the 400 and it becomes a 405, Now you can control all our other iZone automation products such as lighting, irrigation, garage door control, roller blinds etc It can also be controlled via the iZone Home App |
WIRING LAYOUT
...
INSTALLATION INSTRUCTIONS
1️⃣ The C150 can be installed on top of the indoor fan coil unit
2️⃣ Do not run the blue network cables alongside 240 Volt wiring
3️⃣ Always install zones in consecutive ports starting at Zone 1. The front of the C150 is marked with the zone port numbers
4️⃣ Do not directly hard wire the CT24ACM into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 150 system is required
5️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown
6️⃣ Remove the tabs on the CEPC batteries to activate power to the controller
7️⃣ Only connect the power supply to the CT24ACM port after all components have been connected
8️⃣ Initialise the system
9️⃣ Configure the system
1️⃣ 0️⃣ Connect the bridge to the owners modem and connect the bridge power supply. Pair the bridge to the C155 using the pair button on the CEPC screen
INITIALISATION INSTRUCTIONS
All new or modified systems must be initialised prior to system configuration
To initialise the system remove the power from the C150 module, wait 15 seconds and restore power to the C150 module
The time to initialise the system will vary depending on the number of motors connected
The system will also initialise when power is restored after a power failure
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZONE NAKED 410 & 415 SERIES |
iZone Naked 410 & 415 is an inexpensive integrated AC unit and zone controller that utilizes the end user's own smartphone or tablet to control the zones via the iZone App
The CEPC, if used, is provided primarily for the commissioning and set-up of the AC system by the installers and as a backup in the event of Wi-Fi failing
Zones can be temperature controlled by adding iZone sensors and an induct temperature sensor
The Naked 410 & 415 series is for zone and AC unit control
iZone 410 & 415 can be configured as 0-8 zones or 9-14 zones by adding a zone extension
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Add a smart hub to the 410 and it becomes a 415, Now you can control all our other iZone automation products such as lighting, irrigation, garage door control, roller blinds etc It can also be controlled via the iZone Home App |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZONE150 SERIES - INTERGRATED AC UNIT & ZONE CONTROL |
iZone 155 is a low cost integrated AC control system which is suitable for controlling zones and complete AC unit control as well as full smart home control via a phone or tablet
A summary of the features iZone 155 offers are listed below:
...
Up to 6 zones available
...
Zones air quantities can be balanced from the CEPC controller (no need for separate manual balancing dampers)
...
Zone airflows can be adjusted by the end user from the CEPC controller
...
Multiple CEPC controllers can be added
...
Zone temperatures can be controlled from CEPC if iZone sensors are fitted to the system
...
Label zone names from a standard library of names built into the controller
...
Electronic constants can be setup
...
NAKED 420 & 425 SERIES |
iZone 420 & 425 is an integrated air conditioning unit and zone controller that uses a Nano touch screen (CCTSS#) for the graphic user interface
Zones can be temperature controlled by adding iZone sensors and an induct temperature sensor
The iZone 420 & 425 series is for zone and AC unit control
iZone 420 & 425 can be configured as 0-8 zones or 9-14 zones by adding a zone extension
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
There is no facility to control the system via Wi-Fi |
WIRING LAYOUT
...
INSTALLATION INSTRUCTIONS
1️⃣ The C150 can be installed on top of the indoor fan coil unit
2️⃣ Do not run the blue network cables alongside 240 Volt wiring
3️⃣ Always install zones in consecutive ports starting at Zone 1. The front of the C150 is marked with the zone port numbers
4️⃣ Do not directly hard wire the CT24ACM into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 150 system is required
5️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown
6️⃣ Connect the AC unit control cable to the C150 as per the instructions for your brand of AC unit found here
7️⃣ Remove the tabs on the CEPC batteries to activate power to the controller
8️⃣ Only connect the power supply to the CT24ACM port after all components have been connected
9️⃣ Initialise the system
1️⃣ 0️⃣ Configure the system
INITIALISATION INSTRUCTIONS
All new or modified systems must be initialised prior to system configuration
To initialise the system remove the power from the C150 module, wait 15 seconds and restore power to the C150 module
The time to initialise the system will vary depending on the number of motors connected
The system will also initialise when power is restored after a power failure
| |
Add a smart hub to the 420 and it becomes a 425, Now you can control all our other iZone automation products such as lighting, irrigation, garage door control, roller blinds etc It can also be controlled via the iZone Home App |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZONE155 SERIES - INTERGRATED AC UNIT & ZONE CONTROLNAKED 430 & 435 SERIES |
iZone 155 430 is a low cost integrated AC control system which is suitable for controlling zones and complete AC unit control as well as full smart home control via a phone or tablet
A summary of the features iZone 155 offers are listed below:
...
Up to 6 zones available
...
Zones air quantities can be balanced from the CEPC controller (no need for separate manual balancing dampers)
...
Zone airflows can be adjusted by the end user from the CEPC controller
...
Multiple CEPC controllers can be added
...
Zone temperatures can be controlled from CEPC if iZone sensors are fitted to the system
...
Label zone names from a standard library of names built into the controller
...
Electronic constants can be setup
...
an integrated air conditioning unit and zone controller that uses a Nexus or Nexus+ touch screen (CCTSL# or CCTSL#+) for the graphic user interface
Zones can be temperature controlled by adding iZone sensors and an induct temperature sensor
The iZone 430 & 435 series is for zone and AC unit control
iZone 430 & 435 can be configured as 0-8 zones or 9-14 zones by adding a zone extension
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Because the iZone 155 is supplied with an iZone Bridge Add a smart hub to the 430 and it becomes a 435, Now you can control all our other iZone automation products such as lighting, irrigation, garage door control, roller blinds etc It can also be controlled |
WIRING LAYOUT
...
INSTALLATION INSTRUCTIONS
1️⃣ The C150 can be installed on top of the indoor fan coil unit
2️⃣ Do not run the blue network cables alongside 240 Volt wiring
3️⃣ Always install zones in consecutive ports starting at Zone 1. The front of the C150 is marked with the zone port numbers
4️⃣ Do not directly hard wire the CT24ACM into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 150 system is required
5️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown
6️⃣ Connect the AC unit control cable to the C150 as per the instructions for your brand of AC unit found here
7️⃣ Remove the tabs on the CEPC batteries to activate power to the controller
8️⃣ Only connect the power supply to the CT24ACM port after all components have been connected
9️⃣ Initialise the system
1️⃣ 0️⃣ Configure the system
1️⃣ 1️⃣ Connect the bridge to the owners modem and connect the bridge power supply. Pair the bridge to the C155 using the pair button on the CEPC screen
INITIALISATION INSTRUCTIONS
All new or modified systems must be initialised prior to system configuration
To initialise the system remove the power from the C150 module, wait 15 seconds and restore power to the C150 module
The time to initialise the system will vary depending on the number of motors connected
...
via the iZone Home App |