Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

Current Firmware Version - 1.0

CODE

SENSOR TYPE

CONNECTION

C325HI2 v1.0

RA, Zones, Master, RF

A-B-C / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

ADH series only

 

 

AD100HN5FA-SET

10kW High Static Single Phase

AD100S2SH5FA

1U100S2SN5FA

AD125HP5FA-SET

12.5kW High Static Single Phase

AD125S2SH5FA

1U125S2SP5FA

AD125HN5FA-SET

12.5kW High Static Single Phase

AD125S2SH5FA

1U125S2SP5FA

AD140HP5FA-SET

14kW High Static Single Phase

AD140S2SH5FA

1U140S2SP5FA

AD160HP5FA-SET

15.5kW High Static Single Phase

AD160S2SH5FA

1U160S2SP5FA

Tip

Can do Return Air, Zones, Master or RF as controlling sensor.

...

  1. Connect the 3-core cable between Haier ABC connection on indoor board and other end to the iZone C325 module.

  2. Make sure the polarity is correct on both ends. Follow the ABC connection guide below.

photo_2024-08-07_15-42-38.jpgImage Removedimage001.pngImage Added

photo_2024-08-07_15-42-43.jpg

photo_2024-08-07_15-42-40.jpgImage Added