C325HI2 - Haier R32 Gas Type
Haier Compatibility
Current Firmware Version - 1.1
CODE | SENSOR TYPE | CONNECTION |
C325HI2 v1.1 | RA, Zones, Master, RF | A-B-C / Polarity Critical |
SERIES & kW | INDOOR | OUTDOOR |
AD100HN5FA-SET 10kW High Static Single Phase | AD100S2SH5FA | 1U100S2SN5FA |
AD125HP5FA-SET 12.5kW High Static Single Phase | AD125S2SH5FA | 1U125S2SP5FA |
AD125HN5FA-SET 12.5kW High Static Single Phase | AD125S2SH5FA | 1U125S2SP5FA |
AD140HP5FA-SET 14kW High Static Single Phase | AD140S2SH5FA | 1U140S2SP5FA |
AD160HP5FA-SET 15.5kW High Static Single Phase | AD160S2SH5FA | 1U160S2SP5FA |
AD180HP5FA-SET 18kW High Static Single Phase | AD180S2SH5FA | 1U180S2SP5FA |
Can do Return Air, Zones, Master or RF as controlling sensor.
Polarity is critical see below, for correct connection
Power the iZone module before or at the same time as the AC Unit, otherwise the transceiver maybe damaged.
Please ONLY use the AC control cable that comes in your iZone kit or AC unit module box to wire between the indoor unit ABC module and C325HI2 AC unit module.
Installation Instructions: Connecting the 3-Core Cable
Power Off: Ensure the AC unit is completely powered off before connecting the 3-core cable.
Connect Cable:
Connect one end of the 3-core cable to the Haier ABC connection on the indoor board.
Connect the other end to the iZone C325HI2 module.
Check Polarity: Verify that the polarity is correct on both ends. Refer to the ABC connection guide below for reference.
Power On Sequence:
If the iZone System is on a separate circuit from the AC unit, power the module before switching on the AC.
If both are on the same circuit, they can be powered on simultaneously.
CN22-1 connection
CN1 connection