CT24ACM: Mini Transformer - Install Guide
PAGE CONTENTS
PHOTO & DESCRIPTION
AC transformer: The transformer provides 24V power to the C150 module and is used to power all the zone dampers and connected modules
24V AC lead: The 24V lead consists of active and neutral conductors.
EMC ferrite
Molex Micro-Fit Connector: MICROFIT 3.0 RECPT 1 ROW V-0 TPA 02 CKT two wire connector is active and neutral. The connector on the transformer is female and it connects into the male connector on the C150 module
240V AC lead: The 240V lead consists of active, neutral and earth conductors
AU Plug: Standard 3 Pin AU plug
The power supply to the transformer should be via an earthed AU GPO and should not be fed off the same circuit as the AC unit power supply.
Model numbers | CT24ACM |
Input | 240V ~ 50Hz |
Output | AC 24V, 1000mA |
Casing material | Fire retardant ABS plastic |
Operating temperature | Up to 65oC |
240V lead length | 1400 mm (Approx) |
24V lead length | 1400 mm (Approx) |
O/A Dimensions | Height 65 mm Width 75 mm Length 99 mm |
Weight | 1118 g |