Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 6 Next »

Haier Compatibility: ADH series only

Current Firmware Version - 1.3

Can use RA, as controlling sensor

Cannot use Zones, Master or RF as controlling sensor

Polarity is critical see below, for correct connection

Requires Haier proprietary controller for setup - YRE-27

Requires Haier Interface board YCJ-A002

  1. Connect a shielded, 2 core, twisted pair control cable from the C225 / C325HI to the A / B terminals on the Haier Interface board YCJ-A002.

  2. Connect the interconnecting cable supplied by Haier to CN24 in the fan coil unit of the Haier Interface board YCJ-A002.

  3. Set the dipswitches as shown below. Polarity is critical.

  4. Haier YR-E17 wired RC must be connected and set to run on return air

  • No labels