Haier Compatibility:

Current Firmware Version - 1.3

CODE

SENSOR TYPE

CONNECTION

C325HI v1.3

RA ONLY

A-B-C / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

ADH Series Only

Cannot use Zones, Master or RF as controlling sensor, RA ONLY

Polarity is critical see below, for correct connection

Requires Haier proprietary controller for setup - YRE-27

Requires Haier Interface board YCJ-A002

  1. Connect a shielded, 2 core, twisted pair control cable from the C225 / C325HI to the A / B terminals on the Haier Interface board YCJ-A002.

  2. Connect the interconnecting cable supplied by Haier to CN24 in the fan coil unit of the Haier Interface board YCJ-A002.

  3. Set the dipswitches as shown below. Polarity is critical.

  4. Haier YR-E17 wired RC must be connected and set to run on return air