Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

C325HI: HAIER

Haier Compatibility: ADH series only

Can use RA, as controlling sensor

Cannot use Zones, Master or RF as controlling sensor

Polarity is critical see below, for correct connection

Requires Haier proprietary controller for setup - YRE-27

Requires Haier Interface board YCJ-A002

  1. Connect a shielded, 2 core, twisted pair control cable from the C225 / C325HI to the A / B terminals on the Haier Interface board YCJ-A002.

  2. Connect the interconnecting cable supplied by Haier to CN24 in the fan coil unit of the Haier Interface board YCJ-A002.

  3. Set the dipswitches as shown below. Polarity is critical.

  4. Haier YR-E17 wired RC must be connected and set to run on return air

  • No labels