Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

Part

Code

Rev

Release date

Changes

S/W

Extender

CEXT

A

Apr-2019

  • Changed damper port connectors to 6-pin

  • Changed current sensing resistor to 1W

1.5

Multiplexer

CISM

A

Jan-2017

  • First release

1.4

Universal controller

CUCM

A

Aug-2016

  • First release

2.7

VRF host

CVRFH

A

Mar-2024

  • First release

1.0

WiFi bridge

COCB

A

Apr-2021

  • Changed EEPROM chip to 64K

4.27

Smart hub

COCBH

A

Jul-2023

  • First release

4.27

Network extension

CNEM

A

Aug-2011

  • First release

2.0

Extender (CEXT)

CEXT 1.5 - Oct 2022

  • Disable over current monitor for Belimo motors

Multiplexer (CISM)

CISM 1.4 - Nov 2019

  • Fixed an issue with random system disappearing from the screen

Universal Module (CUCM)

CUCM 2.7 - Jun 2024

  • Changed the setpoint hysteresis to 0.5 deg C (IRD-162)

VRF Host Module (CVRFH)

CVRFH 1.0 - Oct 2024

  • First release

WiFi bridge (COCB)

COCB 4.27 - Jul 2024

  • Fix weather temperature data types for negative temperatures

  • Fix C225 config version for old firmware in C225

  • Added the ability to pair a COCB to a C225 in JSON API

  • Add flag to indicate comms to AC unit

  • Added bridge repair equivalent option

  • Reset bridge after changes to DHCP and WiFi settings

  • Add TCP socket monitor. Reset socket when timeout occurs.

  • Better handle old firmware in C225

  • Sleep timer countdown

  • Flash LED’s when changing WiFi settings and DHCP setting

COCB 4.26 - Jun 2024

  • hot water system release (IRD-189)

  • do not allow sending info to C225 and requesting info from C225 at the same time

  • fix Apple home re-connection

Smart hub (COCBH)

COCB 4.27 - Jul 2024

  • Fix weather temperature data types for negative temperatures

  • Fix C225 config version for old firmware in C225

  • Added the ability to pair a COCB to a C225 in JSON API

  • Add flag to indicate comms to AC unit

  • Added bridge repair equivalent option

  • Reset bridge after changes to DHCP and WiFi settings

  • Add TCP socket monitor. Reset socket when timeout occurs.

  • Better handle old firmware in C225

  • Sleep timer countdown

  • Flash LED’s when changing WiFi settings and DHCP setting

COCB 4.26 - Jun 2024

  • hot water system release (IRD-189)

  • do not allow sending info to C225 and requesting info from C225 at the same time

  • fix Apple home re-connection

Network extension (CNEM)

CNEM 2.0 - Aug 2011

  • First release

  • No labels