Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZone has designed interface boards for most major Air Conditioning brands. For queries about specific unit models please contact our Support Team Phone - +61 8 6556 6415 (Press 2 for Support) Email - supportdesk@izone.com.au |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZone DOES NOT take responsibility for installing units that are not listed below or if the AC unit manufactured date is OLDER than 2016. Please advise the iZone parts supplier of the indoor or outdoor unit model to prevent the incompatibility issues. |
...
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | ||
SERIES & kW | INDOOR | OUTDOOR |
ARTG Series Wiring: Connect AC control cable to 2 and 3 - Polarity IS Critical | ||
High Static Single Phase - Compact Outdoor | ARTG30LHTA ARTG36LHTA ARTG45LHTA | |
High Static Single Phase | ARTG30LHTA ARTG36LHTA ARTG45LHTA ARTG54LHTC | |
High Static Infinity Range - Single Phase ONLY | ARTG45LDTA (single phase) ARTG54LDTA (single phase) ARTG60LDTA (single phase) | |
High Static Three Phase | ARTC72LATU ARTC90LATU | |
ARTH Series Wiring: Connect AC control cable to Y2-Y3 and SW1 dip switch ON - Polarity IS Critical only compatible with C325F2 v1.11 module | ||
High Static Single Phase | ARTH60KHTA ( Single Phase ) | |
Standard Range | ARTH54KHTA (Single phase) | |
High Efficiency | ARTH60KHTB (Single phase) |
...
CODE | SENSOR TYPE | CONNECTION | ||
RA Only | CN1 / Polarity Critical - Requires proprietary controller | |||
SERIES & kW | INDOOR | OUTDOOR | ||
Single phase R410A Gas Type | GUD###PHS/B-S | GUD###W/NHB-S | ATTENTION: Above ||
| ||||
SERIES & kW | INDOOR | OUTDOOR | ||
American Design R32 Gas Type | GUD###PHS1/C-S | GUD###W1/NHC-S |
...
CODE | SENSOR TYPE | CONNECTION |
---|---|---|
RA, Zones, Master, RF | H1/H2 - Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
R32 Gas Type Only | GUD50PS/B-S | GUD50W/NhBNHB-S |
GUD71PHS/B-S | GUD71W/NhBNHB-S | |
GUD100PHS/B-S | GUD100W/NhBNHB-S | |
GUD125PHS/B-S | GUD125W/NhBNHB-S | |
GUD140PHS/B-S | GUD140W/NhBNHB-S | |
GUD160PHS/B-S | GUD160W/NhBNHB-S |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
HITACHI |
...
CODE | SENSOR TYPE | CONNECTION | ||
RA, Zones, Master, RF | A - B / Polarity not Critical | |||
SERIES & kW | INDOOR | OUTDOOR | ||
10kw - 14kw | PEA-M##GAA | |||
10kw - 14kw | PEA-M##HAA | |||
10kw - 14kw | PEA-M##JAA | |||
16kw | PEAM160HAAYKIT | |||
18kw | PEAM180LAAYKIT | |||
20/25kw | PEAM200/250YKIT | |||
PEAM200LAA-TH | ||||
| ||||
PEA-RP200WJA | PUZ-RP200YKA | |||
PEA-RP250WHA | PUZ-RP250YKM |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
MIDEA |
...