Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Panel
panelIconIdatlassian-check_mark
panelIcon:check_mark:
bgColor#ABF5D1

iZone has designed interface boards for most major Air Conditioning brands. For queries about specific unit models please contact our Support Team

Phone - +61 8 6556 6415 (Press 2 for Support)

Email - supportdesk@izone.com.au

Panel
panelIconIdatlassian-warning
panelIcon:warning:
bgColor#FFF0B3

iZone DOES NOT take responsibility for installing units that are not listed below or if the AC unit manufactured date is OLDER than 2016. Please advise the iZone parts supplier of the indoor or outdoor unit model to prevent the incompatibility issues.

...

CODE

SENSOR TYPE

CONNECTION

C325F2 v1.11

RA, Zones, Master, RF

SERIES & kW

INDOOR

OUTDOOR

ARTG Series Wiring: Connect AC control cable to 2 and 3 - Polarity IS Critical

High Static Single Phase - Compact Outdoor

ARTG30LHTA

ARTG36LHTA

ARTG45LHTA

High Static Single Phase

ARTG30LHTA

ARTG36LHTA

ARTG45LHTA

ARTG54LHTC

High Static Infinity Range - Single Phase ONLY

ARTG45LDTA (single phase)

ARTG54LDTA (single phase)

ARTG60LDTA (single phase)

High Static Three Phase

ARTC72LATU

ARTC90LATU

ARTH Series Wiring: Connect AC control cable to Y2-Y3 and SW1 dip switch ON - Polarity IS Critical

only compatible with C325F2 v1.11 module

High Static Single Phase

ARTH60KHTA ( Single Phase )

Standard Range

ARTH54KHTA (Single phase)

High Efficiency

ARTH60KHTB (Single phase)

...

CODE

SENSOR TYPE

CONNECTION

C325G v1.3

RA Only

CN1 / Polarity Critical - Requires proprietary controller

SERIES & kW

INDOOR

OUTDOOR

Inverter ducted, single phase units only R410A gas type onlySingle phase R410A Gas Type

GUD###PHS/B-S

GUD###W/Nh B/NHB-S

Note

R410A Gas Type models requires Gree proprietary controller for setup

SERIES & kW

INDOOR

OUTDOOR

American Design R32 Gas Type

GUD###PHS1/C-S

GUD###W1/NHC-S

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

C325G2 - Gree R32 Gas Type (B-S Series)

CODE

SENSOR TYPE

CONNECTION

C325G2 v1.1

RA, Zones, Master, RF

H1/H2 - Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

R32 Gas Type Only

GUD50PS/B-S

GUD50W/NhBNHB-S

GUD71PHS/B-S

GUD71W/NhBNHB-S

GUD100PHS/B-S

GUD100W/NhBNHB-S

GUD125PHS/B-S

GUD125W/NhBNHB-S

GUD140PHS/B-S

GUD140W/NhBNHB-S

GUD160PHS/B-S

GUD160W/NhBNHB-S

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

HITACHI

...

CODE

SENSOR TYPE

CONNECTION

C325M2 v1.0

RA, Zones, Master, RF

A - B / Polarity not Critical

SERIES & kW

INDOOR

OUTDOOR

10kw - 14kw

PEA-M##GAA

10kw - 14kw

PEA-M##HAA

10kw - 14kw

PEA-M##JAA

16kw

PEAM160HAAYKIT

18kw

PEAM180LAAYKIT

20/25kw

PEAM200/250YKIT

PEAM200LAA-TH

Note

Below units (R410A Gas Type) are NOT compatible with M2 module and requires C325M. Please contact our sales team on salesdesk@izone.com.au if you need one of C325M modules.

PEA-RP200WJA

PUZ-RP200YKA

PEA-RP250WHA

PUZ-RP250YKM

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

MIDEA

...