PAGE CONTENTS
ONLINE INSTALLATION WIZARD
Scan the QR code below and you will be sent our online installation wizard for the C430 Series
Answer a few easy questions on:
1️⃣ What air conditioning unit are installing
2️⃣ Is the iZone home mobile app required
3️⃣ Type of constant/bypass zone
4️⃣ Number of Zones using temperature sensors
5️⃣ Number of Zones that are just open/close
➡️ Then click submit for a wiring diagram of the system and a step by step guide on how to install the iZone
The online installation wizard will cover all of the below installation steps:
1️⃣ Design Diagram
2️⃣ Before You Start
3️⃣ Wiring
4️⃣ Configure System
5️⃣ Pair Temperature Sensors (if required)
6️⃣ Commissioning the System
7️⃣ Installing the Wi-Fi Smart Hub
C43# KIT CONTENTS
1x C225: CPU
1x CT24ACE: 24v Power Supply
1x CFC12S: 12m Cat5e Cable
1x CCTSL#: Nexus or Nexus+ Touch Screen
1x C325#: AC Unit Interface (Brand Specific)
1x COCB: Smart Hub (Optional Extra)
1x CEXT: Zone Extender (Optional Extra)
1x CDTS: In-Duct Temperature Sensor (Optional Extra)
1x CR: Repeater (Optional Extra)
#x CRFS#: Wireless Temperate Sensors (Optional Extra and Number Supplied)
GENERAL INSTALLATION GUIDE
1️⃣ The C225, C325# and CEXT can be installed close to the indoor fan coil unit
2️⃣ If any wireless sensor (CRFS#) or wireless bridge (COCB) is not within the range of the C225 then additional repeaters (CR) should be added to help relay the signal from the field device to the C225 and the bridge
3️⃣ Do not run the cat5e cables alongside 240 Volt wiring
4️⃣ When installing network cables down wall cavities or chasing network cables into walls, tape up and protect the RJ45 connector to avoid damage to the connectors
Installation damage to cables is not covered under warranty
5️⃣ Always install zones in consecutive ports starting at Zone number one (1)
The C225 and CEXT are marked with the zone port numbers
6️⃣ Do not directly hard wire the CT24ACE into the AC unit’s power supply
This may void the warranty as it will require an electrician in the event that a repair of the iZone power supply is required
7️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown in the Wiring layout diagrams
8️⃣ Connect the Colour Touch Screens (CCTSL# or CCTSL#+) to the iZone Net ports using the RJ45 cables
If you are connecting more than 3 components requiring iZone Net ports to the system you will need to connect a Network Extension Module Kit (CNEMK)
9️⃣ If any zone is temperature controlled, connect an in Duct Temperature Sensor (CDTS) to the CDTS port
Install the sensor into the supply air duct upstream of all dampers, then secure the sensor in place by using reinforced aluminium tape
1️⃣ 0️⃣ When installing temperature controlled zones ensure the CCTSL# or sensor for the associated zone is installed in a location that is representative of the temperature in the room / zone
The sensor should be installed at approximately 1600mm above the floor and should not be subject to draughts, direct sunlight or heat from equipment such as computers, TV screens etc
The supply air outlets to this room must not blow conditioned air directly onto the sensors or touch screens
1️⃣ 1️⃣ Connect the AC unit control cable to the C225 / C325.
See AC unit wiring connection section for details - C325#: AC Unit Interface - Install Guides
This control cable must be a shielded cable and is not normally supplied by iZone
1️⃣ 2️⃣ The building must be fitted with a compatible Wi-Fi modem
For a list of approved and recommended modems - COCB - Smart Hub - Install Guide
1️⃣ 3️⃣ If connecting the iZone system to a Home Automation system use the Ethernet connection on the bridge - iZone API Integration - Install Guide
1️⃣ 4️⃣ Only connect the power supply to the CT24ACE port after all components have been connected
1️⃣ 5️⃣ Any existing or new air conditioning units that require modification or additional boards to facilitate the correct operation of the iZone system, is the responsibility of the installing contractor