iZONE 110 SERIES
110 is a basic low cost zone only control system which is suitable for switching zones Open and Closed
A summary of the features iZone 110 offers are listed below:
Compatible with all leading air conditioning brands
Up to 6 zones available
Add up to 2 wall controllers
Label zone names from a standard library of names
Open zones are identified with a blue LED
Up two zones can be configured as electronic constants
There is no facility to control the zones via Wi-Fi or automatically via temperature sensors. The iZone 110 does not interface with the air conditioning unit and the installation will require a separate controller for the air conditioning unit. Furthermore iZone 110 does not incorporate airflow control so balancing dampers should be included in the design
It is not possible to upgrade an iZone 110 system to the iZone 400 series however you will be able to use the iZone damper motors, zone cables, transformer and CAT 5E cables
WIRING LAYOUT
INSTALLATION INSTRUCTIONS
1️⃣ The C110MC can be installed on top of the indoor fan coil unit
2️⃣ Do not run the blue network cables alongside 240 Volt wiring
3️⃣ When installing network cables down wall cavities or chasing network cables into walls, tape up and protect the RJ45 connector to avoid damage to the connectors
4️⃣ Always install zones in consecutive ports starting at Zone 1. The back of the C110MC is marked with the zone port numbers
5️⃣ Do not directly hardwire the CT24ACE into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 110 system is required
6️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown
7️⃣ Connect the Wall controller(s) (C110WC) to the C110WC ports using the RJ45 cables
8️⃣ Only connect the power supply to the CT24AC port after all components have been connected
9️⃣ Initialise the system
1️⃣ 0️⃣ Configure the system
SYSTEM INITIALISATION
All new or modified systems must be initialised prior to system configuration
To initialise the system press the button on the underside of any wall controller. This button is recessed so you will need to use a pen to press the button
The time to initialise the system will vary depending on the number of motors connected
The system will also initialise when power is restored after a power failure
iZONE 150 SERIES - ZONE ONLY
iZone 150 Zone only is a basic low cost zone only control system which is suitable for switching zones Open and Closed
A summary of the features iZone 150 Zone only offers are listed below:
Up to 6 zones available
Zones air quantities can be balanced from the CEPC controller (no need for separate manual balancing dampers)
Zone airflows can be adjusted by the end user from the CEPC controller
Multiple CEPC controllers can be added
Zone temperatures can be controlled from CEPC if iZone sensors are fitted to the system
Label zone names from a standard library of names built into the controller
Electronic constants can be set-up
There is no facility to control the zones via Wi-Fi
The an AC unit module can be added to the iZone 150 to provide integrated AC unit and zone control
WIRING LAYOUT
INSTALLATION INSTRUCTIONS
1️⃣ The C150 can be installed on top of the indoor fan coil unit
2️⃣ Do not run the blue network cables alongside 240 Volt wiring
3️⃣ Always install zones in consecutive ports starting at Zone 1. The front of the C150 is marked with the zone port numbers
4️⃣ Do not directly hard wire the CT24ACM into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 150 system is required
5️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown
6️⃣ Remove the tabs on the CEPC batteries to activate power to the controller
7️⃣ Only connect the power supply to the CT24ACM port after all components have been connected
8️⃣ Initialise the system
9️⃣ Configure the system
INITIALISATION INSTRUCTIONS
All new or modified systems must be initialised prior to system configuration
To initialise the system remove the power from the C150 module, wait 15 seconds and restore power to the C150 module
The time to initialise the system will vary depending on the number of motors connected
The system will also initialise when power is restored after a power failure
iZONE 155 SERIES - ZONE ONLY
iZone 155 is a basic low cost zone only control system which is suitable for switching zones Open and Closed
A summary of the features of the iZone 155 zone only are listed below:
Up to 6 zones available
Zones air quantities can be balanced from the CEPC controller (no need for separate manual balancing dampers)
Zone airflows can be adjusted by the end user from the CEPC controller
Multiple CEPC controllers can be added
Zone temperatures can be controlled from CEPC if iZone sensors are fitted to the system
Label zone names from a standard library of names built into the controller. Customised names can be input via your smart device
Electronic constants can be set up
WiFi or 5G control of your zones and other smart iZone devices
An AC unit module can be added to the iZone 155 to provide integrated AC unit and zone control
Because the iZone 155 is supplied with an iZone Bridge other iZone automation products such as lighting, irrigation, garage door control, roller blinds etc can be controlled via the iZone Home App
WIRING LAYOUT
INSTALLATION INSTRUCTIONS
1️⃣ The C150 can be installed on top of the indoor fan coil unit
2️⃣ Do not run the blue network cables alongside 240 Volt wiring
3️⃣ Always install zones in consecutive ports starting at Zone 1. The front of the C150 is marked with the zone port numbers
4️⃣ Do not directly hard wire the CT24ACM into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 150 system is required
5️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown
6️⃣ Remove the tabs on the CEPC batteries to activate power to the controller
7️⃣ Only connect the power supply to the CT24ACM port after all components have been connected
8️⃣ Initialise the system
9️⃣ Configure the system
1️⃣ 0️⃣ Connect the bridge to the owners modem and connect the bridge power supply. Pair the bridge to the C155 using the pair button on the CEPC screen
INITIALISATION INSTRUCTIONS
All new or modified systems must be initialised prior to system configuration
To initialise the system remove the power from the C150 module, wait 15 seconds and restore power to the C150 module
The time to initialise the system will vary depending on the number of motors connected
The system will also initialise when power is restored after a power failure
iZONE 150 SERIES - INTERGRATED AC UNIT & ZONE CONTROL
iZone 155 is a low cost integrated AC control system which is suitable for controlling zones and complete AC unit control as well as full smart home control via a phone or tablet
A summary of the features iZone 155 offers are listed below:
Up to 6 zones available
Zones air quantities can be balanced from the CEPC controller (no need for separate manual balancing dampers)
Zone airflows can be adjusted by the end user from the CEPC controller
Multiple CEPC controllers can be added
Zone temperatures can be controlled from CEPC if iZone sensors are fitted to the system
Label zone names from a standard library of names built into the controller
Electronic constants can be setup
Numerous brands of AC unit can be controlled. Click on the link to which AC units are compatible and how to wire them
There is no facility to control the system via Wi-Fi
WIRING LAYOUT
INSTALLATION INSTRUCTIONS
1️⃣ The C150 can be installed on top of the indoor fan coil unit
2️⃣ Do not run the blue network cables alongside 240 Volt wiring
3️⃣ Always install zones in consecutive ports starting at Zone 1. The front of the C150 is marked with the zone port numbers
4️⃣ Do not directly hard wire the CT24ACM into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 150 system is required
5️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown
6️⃣ Connect the AC unit control cable to the C150 as per the instructions for your brand of AC unit found here
7️⃣ Remove the tabs on the CEPC batteries to activate power to the controller
8️⃣ Only connect the power supply to the CT24ACM port after all components have been connected
9️⃣ Initialise the system
1️⃣ 0️⃣ Configure the system
INITIALISATION INSTRUCTIONS
All new or modified systems must be initialised prior to system configuration
To initialise the system remove the power from the C150 module, wait 15 seconds and restore power to the C150 module
The time to initialise the system will vary depending on the number of motors connected
The system will also initialise when power is restored after a power failure
iZONE 155 SERIES - INTERGRATED AC UNIT & ZONE CONTROL
iZone 155 is a low cost integrated AC control system which is suitable for controlling zones and complete AC unit control as well as full smart home control via a phone or tablet
A summary of the features iZone 155 offers are listed below:
Up to 6 zones available
Zones air quantities can be balanced from the CEPC controller (no need for separate manual balancing dampers)
Zone airflows can be adjusted by the end user from the CEPC controller
Multiple CEPC controllers can be added
Zone temperatures can be controlled from CEPC if iZone sensors are fitted to the system
Label zone names from a standard library of names built into the controller
Electronic constants can be setup
Numerous brands of AC unit can be controlled. Click on the link to which AC units are compatible and how to wire them
Because the iZone 155 is supplied with an iZone Bridge other iZone automation products such as lighting, irrigation, garage door control, roller blinds etc can be controlled
WIRING LAYOUT
INSTALLATION INSTRUCTIONS
1️⃣ The C150 can be installed on top of the indoor fan coil unit
2️⃣ Do not run the blue network cables alongside 240 Volt wiring
3️⃣ Always install zones in consecutive ports starting at Zone 1. The front of the C150 is marked with the zone port numbers
4️⃣ Do not directly hard wire the CT24ACM into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that repair of the iZone 150 system is required
5️⃣ Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ12 cables as shown
6️⃣ Connect the AC unit control cable to the C150 as per the instructions for your brand of AC unit found here
7️⃣ Remove the tabs on the CEPC batteries to activate power to the controller
8️⃣ Only connect the power supply to the CT24ACM port after all components have been connected
9️⃣ Initialise the system
1️⃣ 0️⃣ Configure the system
1️⃣ 1️⃣ Connect the bridge to the owners modem and connect the bridge power supply. Pair the bridge to the C155 using the pair button on the CEPC screen
INITIALISATION INSTRUCTIONS
All new or modified systems must be initialised prior to system configuration
To initialise the system remove the power from the C150 module, wait 15 seconds and restore power to the C150 module
The time to initialise the system will vary depending on the number of motors connected
The system will also initialise when power is restored after a power failure