Induct Temperature is showing out of range temperatures

If your Induct Temperature is displaying out-of-range values, such as -90 or +90 degrees, there may be several underlying causes. You can address this issue by following these steps:

  • Check the Placement:
    Ensure that the Induct sensor’s thermostat end is not in contact with any condensed water or the internal parts of the indoor coils. Such contact can lead to false data and inaccurate readings on the controller.

  • Replace the CDTS Sensor:
    If the sensor placement is correct, the next step is to replace the CDTS to resolve the issue.

  • Change the CPU C225:
    If the problem persists even after replacing the sensor, the CDTS port on the CPU may be causing the inaccurate readings. In this case, we recommend replacing the CPU to rectify the issue.