Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

Panel
panelIconIdatlassian-check_mark
panelIcon:check_mark:
bgColor#ABF5D1

iZone has designed interface boards for most major Air Conditioning brands. For queries about specific unit models please contact our Support Team

Phone - +61 8 6556 6415 (Press 2 for Support)

Email - supportdesk@izone.com.au

Panel
panelIconIdatlassian-warning
panelIcon:warning:
bgColor#FFF0B3

iZone is not responsible for installing units that are not listed below or for AC units manufactured before 2016. Please provide the iZone parts supplier with the model of the indoor or outdoor unit to avoid compatibility issues..

Panel
panelIconIdatlassian-info
panelIcon:info:
bgColor#B3D4FF

PAGE CONTENTS

Live Search

Table of Contents
minLevel1
maxLevel6
outlinefalse
styledefault
type

...

list
printabletrue
Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

ACTRON

CODE

SENSOR TYPE

CONNECTION

C325A -1.3

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

Ultra Slim \ low profile series only

LRE-###AS

URC-###AS

...

CODE

SENSOR TYPE

CONNECTION

C325F2 v1.11

RA, Zones, Master, RF

SERIES & kW

INDOOR

OUTDOOR

ARTG Series Wiring: Connect AC control cable to 2 and 3 - Polarity IS Critical

High Static Single Phase - Compact Outdoor

ARTG30LHTA

ARTG36LHTA

ARTG45LHTA

High Static Single Phase

ARTG30LHTA

ARTG36LHTA

ARTG45LHTA

ARTG54LHTC

High Static Infinity Range - Single Phase ONLY

ARTG45LDTA (single phase)

ARTG54LDTA (single phase)

ARTG60LDTA (single phase)

High Static Three Phase

ARTC72LATU

ARTC90LATU

ARTH Series Wiring: Connect AC control cable to Y2-Y3 and SW1 dip switch ON - Polarity IS Critical

only compatible with C325F2 v1.11 module

High Static Single Phase

ARTH60KHTA ( Single Phase )

Standard Range

ARTH54KHTA (Single phase)

High Efficiency

ARTH60KHTB (Single phase)

...

CODE

SENSOR TYPE

CONNECTION

C325G2 v1.1

RA, Zones, Master, RF

H1/H2 - Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

R32 Gas Type Only

GUD50PS/B-S

GUD50W/NHB-S

GUD71PHS/B-S

GUD71W/NHB-S

GUD100PHS/B-S

GUD100W/NHB-S

GUD125PHS/B-S

GUD125W/NHB-S

GUD140PHS/B-S

GUD140W/NHB-S

GUD160PHS/B-S

GUD160W/NHB-S

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

HISENSE

CODE

SENSOR TYPE

CONNECTION

C325HS v1.0

Coming Soon

Coming Soon

SERIES & kW

INDOOR

OUTDOOR

High Static Pressure

AUD-85UX4RSH1

AUW-85U4RK1

8.5 to 16 Kw

AUD-100UX4RSH1

AUW-100U4RK1

AUD-125UX4RSH1

AUW-125U4RH11

AUD-140UX4RSH1

AUW-140U4RH1

AUD-160UX4RSH1

AUW-160U4RH

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

HITACHI

...

CODE

SENSOR TYPE

CONNECTION

C325M2 v1.0

RA, Zones, Master, RF

A - B / Polarity not Critical

SERIES & kW

INDOOR

OUTDOOR

10kw - 14kw

PEA-M##GAA

10kw - 14kw

PEA-M##HAA

10kw - 14kw

PEA-M##JAA

16kw

PEAM160HAAYKIT

18kw

PEAM180LAAYKIT

20/25kw

PEAM200/250YKIT

PEAM200LAA-TH

Note

Below units (R410A Gas Type) are NOT compatible with M2 module and requires C325M. Please contact our sales team on salesdesk@izone.com.au if you need one of C325M modules.

PEA-RP200WJA

PUZ-RP200YKA

PEA-RP250WHA

PUZ-RP250YKM

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

MIDEA

...