CLIGHT: Basic Downlight - Install Guide

PAGE CONTENTS

 

PHOTO & DESCRIPTION

The iZone basic LED down lights is a low cost "dumb" LED

If used in conjunction with and iZone LED Dimmer module or iZone LED Dimmer + Switch module it can be controlled via your iZone system

The colour temperate can be altered by a three position dip switch on the top of transformer casing

 

Plastic Facia: Only available in white

Spring clips: Strong spring clips with rubber boots

Diffuser: Plastic diffuser

Composite body: The body is a composite of metal and plastic

Transformer: The transformer is built into the LED body

 

SPECIFICATIONS

Model numbers

CLIGHT

Certification

AS/NZS 60598.2.2;  C Tick, SAA, CE, IP44;  IC-4

Power supply

Input: 220 - 240VAC ~ 50/60Hz

Connection

2 Pin Australian GPO plug

Transformer

Built in

Power lead

0.6 meters

Power consumption

Maximum  10.0 Watts on full brightness (4000K)

 

Brightness

Maximum 794 Lumens

Colour adjustable

Cool (6000K)

Neutral (4000K)

Warm (3000K)

(Manual control via dip switch on the top of the down light)

Efficiency

80 Lumens / Watt (Cool White)

Beam Angle

120

Dimmable / controllable

Yes - fully compatible with iZone Relay, Dimmer and Dimmer + switch  module (CACR, CACD & CADSW)

Operating Temperature

-20oC to +50oC

Environment

IP44 rated

Suitable for indoor use only. Suitable for alfresco, porch and bathroom use.

Rating

 

Suitable for residential or commercial use in Australia and New Zealand. Used where air transfer is not permitted or not desired between living space and roof space (there will be no air transfer between spaces even if there is no insulation covering the luminaire). These luminaires have been tested to 90oC and will automatically reduce in brightness to prevent over temperature.

Size & Weight

Height: 58 mm

Diameter 115 mm

Hole cut size: 90 mm

Weight 192 g

 

INSTALLATION

This product must be installed by a qualified licenced electrician in accordance with AS/NZ 3000:2007 Electrical installations

Please note: Accidental contact with live parts does not rely on the luminaire enclosure

Warning this product is not suitable for mounting on tubular material

Ensure power supply is isolated before starting any work

Ensure downlight is located with minimum clearances from combustible building material as shown below

Connect mains power cable

Rotate spring clips up and gently insert downlight into hole