Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

iZone has designed interface boards for most major Air Conditioning brands

Panel
panelIconIdatlassian-check_mark
panelIcon:check_mark:
bgColor#ABF5D1

iZone has designed interface boards for most major Air Conditioning brands. For queries about specific unit models please contact our Support Team

Phone - +61 8 6556 6415 (Press 2 for Support)

Email - supportdesk@izone.com.au

Panel
panelIconIdatlassian-warning
panelIcon:warning:
bgColor#FFF0B3

iZone

...

DOES NOT take responsibility for installing units that are not listed below or if the AC unit manufactured date is

...

OLDER than 2016. Please advise the iZone parts supplier of the indoor or outdoor unit model to prevent the incompatibility issues.

Panel
panelIconIdatlassian-info
panelIcon:info:
bgColor#B3D4FF

PAGE CONTENTS

Table of Contents
pipe
minLevel1
maxLevel6
include
outlinefalse
indent
styledefault
exclude
typelist
separatorclass
printablefalsetrue

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

ACTRON

...

CODE

SENSOR TYPE

CONNECTION

C325F2 v1.1011

RA, Zones, Master, RF

SERIES & kW

INDOOR

OUTDOOR

ARTG Series Wiring: Connect AC control cable to 2 and 3 - Polarity IS Critical

High Static Single Phase - Compact Outdoor

ARTG30LHTA

ARTG36LHTA

ARTG45LHTA

High Static Single Phase

ARTG30LHTA

ARTG36LHTA

ARTG45LHTA

ARTG54LHTC

High Static Infinity Range - Single Phase ONLY

ARTG45LDTA (single phase)

ARTG54LDTA (single phase)

ARTG60LDTA (single phase)

High Static Three Phase

ARTC72LATU

ARTC90LATU

ARTH Series Wiring: Connect AC control cable to Y2-Y3 and SW1 dip switch ON - Polarity IS Critical

only compatible with C325F2 v1.11 module

High Static Single Phase

ARTH60KHTA ( Single Phase )

Standard Range

ARTH54KHTA (Single phase)

High Efficiency

ARTH60KHTB (Single phase)

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2
GREE

C325G - Gree R410A and New R32 Gas Type (C-S Series)

Panel
panelIconIdatlassian-warning
panelIcon:warning:
bgColor#FFF0B3

Gree are using the same model numbers for their new R32 Gas type units

CODE

SENSOR TYPE

CONNECTION

C325G v1.3

RA Only

CN1 / Polarity Critical - Requires proprietary controller

SERIES & kW

INDOOR

OUTDOOR

Inverter ducted, single phase units only R410A gas type onlySingle phase R410A Gas Type

GUD###PHS/B-S

GUD###W/Nh BNHB-S

NOTESGUD50PS/B

ATTENTION: Above models requires Gree proprietary controller for setup

SERIES & kW

INDOOR

OUTDOOR

C325G2

American Design R32 Gas Type

GUD###PHS1/C-S

GUD50W/NhB-S

GUD###W1/NHC-S

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

C325G2 - Gree R32 Gas Type (B-S Series)

CODE

SENSOR TYPE

CONNECTION

C325G2 v1.1

RA, Zones, Master, RF

H1/H2 - Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

R32 Gas Type Only

GUD50PS/B-S

GUD50W/NhB-S

GUD71PHS/B-S

GUD71W/NhB-SR32 Gas type Only

GUD100PHS/B-S

GUD100W/NhB-S

GUD125PHS/B-S

GUD125W/NhB-S

GUD140PHS/B-S

GUD140W/NhB-S

GUD160PHS/B-S

GUD160W/NhB-S

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

HITACHI

CODE

SENSOR TYPE

CONNECTION

C325H v2.4

RA, Zones, Master, RF

A - B / Polarity not critical

SERIES & kW

INDOOR

OUTDOOR

R410A Gas Type

RPI ### 1SQ 

RPI ### 2SQ

R32 Gas Type

PPIM-4.0UFA1NQ

PAS-4.0UFASNQ1

PPIM-6.0UFA1NQ

PAS-6.0UFASNQ1

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

HAIER R410 Gas Type

CODE

SENSOR TYPE

CONNECTION

C325HI v1.3

RA Only

A - B / Polarity Critical

Requires proprietary controller / Requires Interface board

SERIES & kW

INDOOR

OUTDOOR

ADH series only

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

HAIER R32 Gas Type

CODE

SENSOR TYPE

CONNECTION

C325HI2 v1.0

RA, Zones, Master, RF

A-B-C / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

AD100HN5FA-SET

10kW High Static Single Phase

AD100S2SH5FA

1U100S2SN5FA

AD125HP5FA-SET

12.5kW High Static Single Phase

AD125S2SH5FA

1U125S2SP5FA

AD125HN5FA-SET

12.5kW High Static Single Phase

AD125S2SH5FA

1U125S2SP5FA

AD140HP5FA-SET

14kW High Static Single Phase

AD140S2SH5FA

1U140S2SP5FA

AD160HP5FA-SET

15.5kW High Static Single Phase

AD160S2SH5FA

1U160S2SP5FA

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

iZONE

CODE

SENSOR TYPE

CONNECTION

C325I v1.3

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

Single Phase - 7kw / 17kw

AD###-I

AD###-O

...

CODE

SENSOR TYPE

CONNECTION

C325M2 v1.0

RA, Zones, Master, RF

A - B / Polarity not Critical

SERIES & kW

INDOOR

OUTDOOR

10kw - 14kw

PEA-M##GAA

10kw - 14kw

PEA-M##HAA

10kw - 14kw

PEA-M##JAA

16kw

PEAM160HAAYKIT

18kw

PEAM180LAAYKIT

20/25kw

PEAM200/250YKIT

PEAM200LAA-TH

Note

Below units (R410A Gas Type) are NOT compatible with M2 module and requires C325M. Please contact our sales team on salesdesk@izone.com.au if you need one of C325M modules.

PEA-RP200WJA

PUZ-RP200YKA

PEA-RP250WHA

PUZ-RP250YKM

Panel
panelIconIdatlassian-note
panelIcon:note:
bgColor#C0B6F2

MIDEA

CODE

SENSOR TYPE

CONNECTION

C325MD v1.3

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

DUC series only

...

CODE

SENSOR TYPE

CONNECTION

C325MHI C325MHI2 v1.5

RA, Zones, Master, RF

A - B / Polarity not Critical

SERIES & kW

INDOOR

OUTDOOR

FDU Series

FDUA Series

FDUM Series

KX Series

...