iZone has designed interface boards for most major Air Conditioning brands
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZone has designed interface boards for most major Air Conditioning brands. For queries about specific unit models please contact our Support Team Phone - +61 8 6556 6415 (Press 2 for Support) Email - supportdesk@izone.com.au |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZone |
...
DOES NOT take responsibility for installing units that are not listed below or if the AC unit manufactured date is |
...
OLDER than 2016. Please advise the iZone parts supplier of the indoor or outdoor unit model to prevent the incompatibility issues. |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
PAGE CONTENTS |
Table of Contents | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
ACTRON |
...
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | ||
SERIES & kW | INDOOR | OUTDOOR |
ARTG Series Wiring: Connect AC control cable to 2 and 3 - Polarity IS Critical | ||
High Static Single Phase - Compact Outdoor | ARTG30LHTA ARTG36LHTA ARTG45LHTA | |
High Static Single Phase | ARTG30LHTA ARTG36LHTA ARTG45LHTA ARTG54LHTC | |
High Static Infinity Range - Single Phase ONLY | ARTG45LDTA (single phase) ARTG54LDTA (single phase) ARTG60LDTA (single phase) | |
High Static Three Phase | ARTC72LATU ARTC90LATU | |
ARTH Series Wiring: Connect AC control cable to Y2-Y3 and SW1 dip switch ON - Polarity IS Critical only compatible with C325F2 v1.11 module | ||
High Static Single Phase | ARTH60KHTA ( Single Phase ) | |
Standard Range | ARTH54KHTA (Single phase) | |
High Efficiency | ARTH60KHTB (Single phase) |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
GREEC325G - Gree R410A and New R32 Gas Type (C-S Series) |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Gree are using the same model numbers for their new R32 Gas type units |
CODE | SENSOR TYPE | CONNECTION |
RA Only | CN1 / Polarity Critical - Requires proprietary controller | |
SERIES & kW | INDOOR | OUTDOOR |
Inverter ducted, single phase units only R410A gas type onlySingle phase R410A Gas Type | GUD###PHS/B-S | GUD###W/Nh BNHB-S |
| ||||
SERIES & kW | INDOOR | OUTDOOR |
C325G2
American Design R32 Gas Type | GUD###PHS1/C-S |
GUD50W/NhB-S
GUD###W1/NHC-S |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
C325G2 - Gree R32 Gas Type (B-S Series) |
CODE | SENSOR TYPE | CONNECTION | |
---|---|---|---|
RA, Zones, Master, RF | H1/H2 - Polarity Critical | ||
SERIES & kW | INDOOR | OUTDOOR | |
R32 Gas Type Only | GUD50PS/B-S | GUD50W/NHB-S | |
GUD71PHS/B-S | GUD71W/NhBNHB-S | ||
R32 Gas type Only | GUD100PHS/B-S | GUD100W/NhBNHB-S | |
GUD125PHS/B-S | GUD125W/NhBNHB-S | ||
GUD140PHS/B-S | GUD140W/NhBNHB-S | ||
GUD160PHS/B-S | GUD160W/NhBNHB-S |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
HITACHI |
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | A - B / Polarity not critical | |
SERIES & kW | INDOOR | OUTDOOR |
R410A Gas Type | RPI ### 1SQ | |
RPI ### 2SQ | ||
R32 Gas Type | PPIM-4.0UFA1NQ | PAS-4.0UFASNQ1 |
PPIM-6.0UFA1NQ | PAS-6.0UFASNQ1 |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
HAIER R410 Gas Type |
CODE | SENSOR TYPE | CONNECTION |
RA Only | A - B / Polarity Critical | |
Requires proprietary controller / Requires Interface board | ||
SERIES & kW | INDOOR | OUTDOOR |
ADH series only |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
HAIER R32 Gas Type |
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | A-B-C / Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
AD100HN5FA-SET 10kW High Static Single Phase | AD100S2SH5FA | 1U100S2SN5FA |
AD125HP5FA-SET 12.5kW High Static Single Phase | AD125S2SH5FA | 1U125S2SP5FA |
AD125HN5FA-SET 12.5kW High Static Single Phase | AD125S2SH5FA | 1U125S2SP5FA |
AD140HP5FA-SET 14kW High Static Single Phase | AD140S2SH5FA | 1U140S2SP5FA |
AD160HP5FA-SET 15.5kW High Static Single Phase | AD160S2SH5FA | 1U160S2SP5FA |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZONE |
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | CN40 / Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
Single Phase - 7kw / 17kw | AD###-I | AD###-O |
...
CODE | SENSOR TYPE | CONNECTION | ||
RA, Zones, Master, RF | A - B / Polarity not Critical | |||
SERIES & kW | INDOOR | OUTDOOR | ||
10kw - 14kw | PEA-M##GAA | |||
10kw - 14kw | PEA-M##HAA | |||
10kw - 14kw | PEA-M##JAA | |||
16kw | PEAM160HAAYKIT | |||
18kw | PEAM180LAAYKIT | |||
20/25kw | PEAM200/250YKIT | |||
PEAM200LAA-TH | ||||
| ||||
PEA-RP200WJA | PUZ-RP200YKA | |||
PEA-RP250WHA | PUZ-RP250YKM |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
MIDEA |
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | CN40 / Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
DUC series only |
...
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | A - B / Polarity not Critical | |
SERIES & kW | INDOOR | OUTDOOR |
FDU Series | ||
FDUA Series | ||
FDUM Series | ||
KX Series |
...