Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZone has designed interface boards for most major Air Conditioning brands. For queries about specific unit models please contact our Support Team Phone - +61 8 6556 6415 (Press 2 for Support) Email - supportdesk@izone.com.au |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZone does isnot take responsibility responsible for installing units that are not listed below or if the for AC unit manufactured date is older than units manufactured before 2016. Please advise provide the iZone parts supplier with the model of the indoor or outdoor unit model to prevent the incompatibility avoid compatibility issues.. |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
PAGE CONTENTS |
Table of Contents | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
ACTRON |
...
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | ||
SERIES & kW | INDOOR | OUTDOOR |
ARTG Series Wiring: Connect AC control cable to 2 and 3 - Polarity IS Critical | ||
High Static Single Phase - Compact Outdoor | ARTG30LHTA ARTG36LHTA ARTG45LHTA | |
High Static Single Phase | ARTG30LHTA ARTG36LHTA ARTG45LHTA ARTG54LHTC | |
High Static Infinity Range - Single Phase ONLY | ARTG45LDTA (single phase) ARTG54LDTA (single phase) ARTG60LDTA (single phase) | |
High Static Three Phase | ARTC72LATU ARTC90LATU | |
ARTH Series Wiring: Connect AC control cable to Y2-Y3 and SW1 dip switch ON - Polarity IS Critical only compatible with C325F2 v1.11 module | ||
High Static Single Phase | ARTH60KHTA ( Single Phase ) | |
Standard Range | ARTH54KHTA (Single phase) | |
High Efficiency | ARTH60KHTB (Single phase) |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
GREE - R410 Gas TypeC325G - Gree R410A and New R32 Gas Type (C-S Series) |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Gree are using the same model numbers for their new R32 Gas type units |
CODE | SENSOR TYPE | CONNECTION | ||
RA Only | CN1 / Polarity Critical - Requires proprietary controller | |||
SERIES & kW | INDOOR | OUTDOOR | ||
Inverter ducted, single phase units only R410A gas type onlySingle phase R410A Gas Type | GUD###PHS/B-S | GUD###W/Nh BNHB-S | ||
| ||||
SERIES & kW | INDOOR | OUTDOOR | ||
American Design R32 Gas Type | GUD###PHS1/C-S | GUD###W1/NHC-S |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
GREE C325G2 - Gree R32 Gas Type (B-S Series) |
CODE | SENSOR TYPE | CONNECTION |
---|---|---|
RA, Zones, Master, RF | H1/H2 - Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
R32 Gas Type Only | GUD50PS/B-S | GUD50W/NhBNHB-S |
GUD71PHS/B-S | GUD71W/NhBNHB-S | |
GUD100PHS/B-S | GUD100W/NhBNHB-S | |
GUD125PHS/B-S | GUD125W/NhBNHB-S | |
GUD140PHS/B-S | GUD140W/NhBNHB-S | |
GUD160PHS/B-S | GUD160W/NhBNHB-S |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
HISENSE |
CODE | SENSOR TYPE | CONNECTION |
---|---|---|
Coming Soon | Coming Soon | |
SERIES & kW | INDOOR | OUTDOOR |
High Static Pressure | AUD-85UX4RSH1 | AUW-85U4RK1 |
8.5 to 16 Kw | AUD-100UX4RSH1 | AUW-100U4RK1 |
AUD-125UX4RSH1 | AUW-125U4RH11 | |
AUD-140UX4RSH1 | AUW-140U4RH1 | |
AUD-160UX4RSH1 | AUW-160U4RH |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
HITACHI |
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | A - B / Polarity not critical | |
SERIES & kW | INDOOR | OUTDOOR |
R410A Gas Type | RPI ### 1SQ | |
RPI ### 2SQ | ||
R32 Gas Type | PPIM-4.0UFA1NQ | PAS-4.0UFASNQ1 |
PPIM-6.0UFA1NQ | PAS-6.0UFASNQ1 |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
HAIER R410 Gas Type |
CODE | SENSOR TYPE | CONNECTION |
RA Only | A - B / Polarity Critical | |
Requires proprietary controller / Requires Interface board | ||
SERIES & kW | INDOOR | OUTDOOR |
ADH series only |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
HAIER R32 Gas Type |
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | A-B-C / Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
AD100HN5FA-SET 10kW High Static Single Phase | AD100S2SH5FA | 1U100S2SN5FA |
AD125HP5FA-SET 12.5kW High Static Single Phase | AD125S2SH5FA | 1U125S2SP5FA |
AD125HN5FA-SET 12.5kW High Static Single Phase | AD125S2SH5FA | 1U125S2SP5FA |
AD140HP5FA-SET 14kW High Static Single Phase | AD140S2SH5FA | 1U140S2SP5FA |
AD160HP5FA-SET 15.5kW High Static Single Phase | AD160S2SH5FA | 1U160S2SP5FA |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
iZONE |
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | CN40 / Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
Single Phase - 7kw / 17kw | AD###-I | AD###-O |
...
CODE | SENSOR TYPE | CONNECTION | ||
RA, Zones, Master, RF | A - B / Polarity not Critical | |||
SERIES & kW | INDOOR | OUTDOOR | ||
10kw - 14kw | PEA-M##GAA | |||
10kw - 14kw | PEA-M##HAA | |||
10kw - 14kw | PEA-M##JAA | |||
16kw | PEAM160HAAYKIT | |||
18kw | PEAM180LAAYKIT | |||
20/25kw | PEAM200/250YKIT | |||
PEAM200LAA-TH | ||||
| ||||
PEA-RP200WJA | PUZ-RP200YKA | |||
PEA-RP250WHA | PUZ-RP250YKM |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
MIDEA |
...
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | A - B / Polarity not Critical | |
SERIES & kW | INDOOR | OUTDOOR |
FDU Series | ||
FDUA Series | ||
FDUM Series | ||
KX Series |
Tip |
---|
Indoor models FDUA200VG, FDUA200VF and FDUA200VH are compatible. |
Info |
---|
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
PANASONIC |
...