C325TZ - Temperzone

C325TZ - Temperzone

Temperzone Compatibility: units with UC8 board or above (not all the units with UC8 boards are compatible)

Please check the indoor model with supportdesk@izone.com.au first.

The new R32 Econex units (for example ISD 351LYX and ISD 251LYX units) and Eco Ultra do not work with the iZone controller at the moment.

Current Firmware Version - 1.3

Not Compatible: UC7 board and before

Can use RA, Zones, Master or RF as controlling sensor

Polarity is critical see below, for correct connection

  • Connect a shielded, 2 core, twisted pair control cable from the  C225 to the UC8 or 9 board in the condensing unit. This cable is supplied by the installer

  • Ensure the dip switches in the condensing unit are set correctly for the installed compressor type (digital / fixed speed) and fan speed control. Refer to the Temperzone service manual

Temperzone UC8 or higher PCB: iZone is only compatible with Temperzone units fitted with UC8 or higher PCB's

Shielded, 2 core, twisted pair: This cable is not supplied by iZone

A: Connect A wire on this side. Polarity is critical

C225 Module: iZone C225 module must have a C325TZ module connected.

B: Connect B wire on this side. Polarity is critical