C325A - Actron
Actron Compatibility: Ultra Slim \ low profile series only
Current Firmware Version - 1.3
SERIES & kW | INDOOR | OUTDOOR |
Ultra Slim \ low profile series only | LRE-###AS | URC-###AS |
Can use RA, Zones, Master and RF as controlling sensor
Connect a shielded, 2 core, twisted pair control cable from the C225 / C325A to the X / Y in the fan coil unit. This cable and connector is supplied by iZone - CACUCM15
Indoor fan coil unit PCB
CN40: Connect to X and Y
C225 AC unit connector: Connect AC unit cable from fan coil to C225 as indicated
Polarity is critical: Make sure it is wired in accordance with these instructions on both the CN40 connector on the fan coil PCB and the C225 cable connector
Cable from CN40: Ensure the cable is shielded, 2 core, twisted pair. This cable is pre-terminated suitable for CN40 connector and is supplied by iZone