iZone has designed interface boards for most major Air Conditioning brands
For queries about specific unit models please contact our Support Team
Phone - +61 8 6556 6415 (Press 2 for Support)
Email - supportdesk@izone.com.au
iZone does not take responsibility for installing units that are not listed below or if the AC unit manufactured date is older than 2016. Please advise the iZone parts supplier of the indoor or outdoor unit model to prevent the incompatibility issues.
QUICK LINKS
ACTRON
BRAEMAR
CARRIER
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | CN40 / Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
HIGH STATIC / 9kw - 16.5kw | 42SHDV### | 38SHDV### |
DAIKIN
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | P1 - P2 / Polarity not critical | |
SERIES & kW | INDOOR | OUTDOOR |
PREMIUM INVERTER SINGLE PHASE / 7kw - 16kw | FDYA###AV1 | RZA###CV1 |
PREMIUM INVERTER SINGLE PHASE / 7kw - 16kw | FDYQ###AV1 | RZQ###CV1 |
PREMIUM INVERTER THREE PHASE / 20kw - 25kw | FDYQ###LCV1 | RZYQ##TY1 |
INVERTER SINGLE PHASE / 5kw - 16kw | FDYAN###AV1 | RZA###CV1 |
INVERTER SINGLE PHASE / 5kw - 16kw | FDYQN###AV1 | RZQ###CV1 |
INVERTER THREE PHASE / 7kw - 25kw | FDYAN###AV1 | RZA###CV1 |
INVERTER THREE PHASE / 7kw - 25kw | FDYQN###AV1 | RZQ###CV1 |
VRV | FXMQ###-PAVE |
FUJITSU
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | ||
SERIES & kW | INDOOR | OUTDOOR |
ARTG Series Wiring: Connect AC control cable to 2 and 3 - Polarity IS Critical | ||
High Static Single Phase - Compact Outdoor | ARTG30LHTA ARTG36LHTA ARTG45LHTA | |
High Static Single Phase | ARTG30LHTA ARTG36LHTA ARTG45LHTA ARTG54LHTC | |
High Static Infinity Range - Single Phase ONLY | ARTG45LDTA (single phase) ARTG54LDTA (single phase) ARTG60LDTA (single phase) | |
High Static Three Phase | ARTC72LATU ARTC90LATU | |
ARTH Series Wiring: Connect AC control cable to Y2-Y3 and SW1 dip switch ON - Polarity IS Critical | ||
High Static Single Phase | ARTH60KHTA ( Single Phase ) | |
Standard Range | ARTH54KHTA (Single phase) | |
High Efficiency | ARTH60KHTB (Single phase) |
GREE
CODE | SENSOR TYPE | CONNECTION |
RA Only | CN1 / Polarity Critical | |
Requires proprietary controller | ||
SERIES & kW | INDOOR | OUTDOOR |
Inverter ducted, single phase units only R410A gas type only | GUD###PHS/B-S | GUD###W/Nh B-S |
Gree are using the same model numbers for their new R32 Gas type units, we are not compatible with these units at this stage
HITACHI
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | A - B / Polarity not critical | |
SERIES & kW | INDOOR | OUTDOOR |
RPI ### 1SQ | ||
RPI ### 2SQ |
HAIER
CODE | SENSOR TYPE | CONNECTION |
RA Only | A - B / Polarity Critical | |
Requires proprietary controller / Requires Interface board | ||
SERIES & kW | INDOOR | OUTDOOR |
ADH series only |
iZONE
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | CN40 / Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
Single Phase - 7kw / 17kw | AD###-I | AD###-O |
KADEN
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | CN40 / Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
Single Phase - 7kw / 17kw | KD### |
LG
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | A - B / Polarity Critical | |
Requires Interface board | ||
SERIES & kW | INDOOR | OUTDOOR |
B##AWYN7G5 |
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | LG Supplied connector / Polarity not Critical | |
SERIES & kW | INDOOR | OUTDOOR |
B##AWYN7G6 |
MITSUBISHI ELECTRIC
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | A - B / Polarity not Critical | |
SERIES & kW | INDOOR | OUTDOOR |
10kw - 14kw | PEA-M##GAA | |
10kw - 14kw | PEA-M##HAA | |
10kw - 14kw | PEA-M##JAA | |
16kw | PEAM160HAAYKIT | |
18kw | PEAM180LAAYKIT | |
20/25kw | PEAM200/250YKIT |
MIDEA
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | CN40 / Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
DUC series only |
MITSUBISHI HEAVY INDUSTRIES
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | A - B / Polarity not Critical | |
SERIES & kW | INDOOR | OUTDOOR |
FDU Series | ||
FDUA Series | ||
FDUM Series | ||
KX Series |
Indoor models FDUA200VG, FDUA200VF and FDUA200VH are compatible.
PANASONIC
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | R1 - R2 / Polarity not Critical | |
SERIES & kW | INDOOR | OUTDOOR |
S - series units | ||
Nano X high static ducted |
RINNAI
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | CN40 / Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
DINLR XX Series only |
SAMSUNG
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | F3 - F4 / Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
R410A Gas Type - 5kW to 14Kw | AC###HBHFKH/SA |
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | F3 - F4 / Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
R410A Gas Type - 16kW to 20Kw | AC###JNHFKH/SA | |
R32 - 5kw to 14kw | AC###TNHPKG/SA |
TOSHIBA
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | A - B / Polarity not Critical | |
SERIES & kW | INDOOR | OUTDOOR |
A series only / S-Net protocol | RAV-SMXXX 3DT | |
10kw - 16kw | RAV-GMXXXDTP-A | |
MMD-UP0271HP-E |
TEMPERZONE
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | ||
SERIES & kW | INDOOR | OUTDOOR |
UC8 board or above |
Not Compatible - UC7 board
YORK
CODE | SENSOR TYPE | CONNECTION |
RA, Zones, Master, RF | CN40 / Polarity Critical | |
SERIES & kW | INDOOR | OUTDOOR |
6850018 | ||
6850038 | ||
6850048 |
UNIVERSAL
CODE | SENSOR TYPE | CONNECTION |
SERIES & kW | INDOOR | OUTDOOR |