iZone has designed interface boards for most major Air Conditioning brands

For queries about specific unit models please contact our Support Team

Phone - +61 8 6556 6415 (Press 2 for Support)

Email - supportdesk@izone.com.au

iZone does not take responsibility for installing units that are not listed below or if the AC unit manufactured date is older than 2016. Please advise the iZone parts supplier of the indoor or outdoor unit model to prevent the incompatibility issues.

QUICK LINKS

ACTRON

 Click here for compatibility

Actron Compatibility: Ultra Slim \ low profile series only

Current Firmware Version - 1.3

SERIES & kW

INDOOR

OUTDOOR

Ultra Slim \ low profile series only

LRE-###AS

URC-###AS

Can use RA, Zones, Master and RF as controlling sensor

Polarity is critical see below, for correct connection

  • Connect a shielded, 2 core, twisted pair control cable from the  C225 / C325A to the  X / Y in the fan coil unit. This cable and connector is supplied by iZone - CACUCM15

1️⃣ Indoor fan coil unit PCB

2️⃣ CN40: Connect to X and Y

3️⃣ C225 AC unit connector: Connect AC unit cable from fan coil to C225 as indicated

4️⃣ Polarity is critical: Make sure it is wired in accordance with these instructions on both the CN40 connector on the fan coil PCB and the C225 cable connector

5️⃣ Cable from CN40: Ensure the cable is shielded, 2 core, twisted pair. This cable is pre-terminated suitable for CN40 connector and is supplied by iZone

BRAEMAR

 Click here for compatibility

Braemar Compatibility: SDHV series inverter ducted, single phase units only

Current Firmware Version - 1.3

SERIES & kW

INDOOR

OUTDOOR

SINGLE PHASE / 7kw - 16kw

SDHV##D1S 

SCHV##D1S 

Can use RA as controlling sensor

Cannot use Zones, Master or RF as controlling sensor

Polarity is critical see below, for correct connection

Requires Braemar proprietary controller for setup

  1. Connect the Braemar proprietary wired controller to the FCU PCB

  2. Enter the service mode parameters

To enter Service Mode, power must be connected to the unit and proprietary wired controller, and the unit must be switched 'OFF' at the wall control. Follow the steps below and refer to the function and parameter setting table

3. As per the instructions set the sensor to return air for all modes

4. Set the iZone control setting

5. Set the required static pressure setting

6. Cycle the power to the AC unit

7. Connect a 2 core, twisted pair control cable from the C225 / C325B X / Y to CN1 in the fan coil unit

A connector and short cable has been provided with the C325B but will need to be extended

Service Mode Parameter Table

Function Display

Function Description

Parameter Display

Parameter Description

0

Temp sensor location

Ensure set to '01'

 

01

Sensor at return air for all modes

02

Sensor at wired control for all modes

03

Sensor at return air for cool, dry & fan modes, at wired control for heat mode

10

iZone control

Ensure set to '01'

00

Standard control

01

iZone control setting

11

Indoor fan power setting

Factory default '05'

Adjust to suit installed static

Low static = '01'

High static = '09'

 

 

 

 

 

 

ESP (Pa)

High Speed

Low Speed

01

10

5

1

02

20

6

2

03

30

7

3

04

40

8

4

05

50 (default)

9

5

06

75

10

6

07

100

11

7

08

150

12

8

09

200

13

9

1️⃣ Indoor fan coil unit PCB: Note connector CN1

2️⃣ Connector and short cable provided: Insert the connector and short cable (see image below) into the connector CN1. Note the correct polarity for X & Y. Polarity is critical

3️⃣ C225 AC unit connector: Connect AC unit cable from fan coil to C225 as indicated

4️⃣ Polarity is critical: Make sure it is wired in accordance with these instructions on both the CN1 connector on the fan coil PCB and the C225 cable connector

5️⃣ Cable from CN1: Connect a shielded, 2 core, twisted pair cable to the connector and short cable provided

CARRIER

CODE

SENSOR TYPE

CONNECTION

C325C v1.0

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

HIGH STATIC / 9kw - 16.5kw

42SHDV###

38SHDV###

DAIKIN

CODE

SENSOR TYPE

CONNECTION

C325D2 v1.2

RA, Zones, Master, RF

P1 - P2 / Polarity not critical

SERIES & kW

INDOOR

OUTDOOR

PREMIUM INVERTER SINGLE PHASE / 7kw - 16kw

FDYA###AV1

RZA###CV1

PREMIUM INVERTER SINGLE PHASE / 7kw - 16kw

FDYQ###AV1

RZQ###CV1

PREMIUM INVERTER THREE PHASE / 20kw - 25kw

FDYQ###LCV1

RZYQ##TY1

INVERTER SINGLE PHASE / 5kw - 16kw

FDYAN###AV1

RZA###CV1

INVERTER SINGLE PHASE / 5kw - 16kw

FDYQN###AV1

RZQ###CV1

INVERTER THREE PHASE / 7kw - 25kw

FDYAN###AV1

RZA###CV1

INVERTER THREE PHASE / 7kw - 25kw

FDYQN###AV1

RZQ###CV1

VRV

FXMQ###-PAVE

FUJITSU

CODE

SENSOR TYPE

CONNECTION

C325F2 v1.10

RA, Zones, Master, RF

SERIES & kW

INDOOR

OUTDOOR

ARTG Series Wiring: Connect AC control cable to 2 and 3 - Polarity IS Critical

High Static Single Phase - Compact Outdoor

ARTG30LHTA

ARTG36LHTA

ARTG45LHTA

High Static Single Phase

ARTG30LHTA

ARTG36LHTA

ARTG45LHTA

ARTG54LHTC

High Static Infinity Range - Single Phase ONLY

ARTG45LDTA (single phase)

ARTG54LDTA (single phase)

ARTG60LDTA (single phase)

High Static Three Phase

ARTC72LATU

ARTC90LATU

ARTH Series Wiring: Connect AC control cable to Y2-Y3 and SW1 dip switch ON - Polarity IS Critical

High Static Single Phase

ARTH60KHTA ( Single Phase )

Standard Range

ARTH54KHTA (Single phase)

High Efficiency

ARTH60KHTB (Single phase)

GREE

CODE

SENSOR TYPE

CONNECTION

C325G v1.3

RA Only

CN1 / Polarity Critical

Requires proprietary controller

SERIES & kW

INDOOR

OUTDOOR

Inverter ducted, single phase units only R410A gas type only

GUD###PHS/B-S

GUD###W/Nh B-S

Gree are using the same model numbers for their new R32 Gas type units, we are not compatible with these units at this stage

HITACHI

CODE

SENSOR TYPE

CONNECTION

C325H v2.4

RA, Zones, Master, RF

A - B / Polarity not critical

SERIES & kW

INDOOR

OUTDOOR

RPI ### 1SQ 

RPI ### 2SQ

HAIER

CODE

SENSOR TYPE

CONNECTION

C325HI v1.3

RA Only

A - B / Polarity Critical

Requires proprietary controller / Requires Interface board

SERIES & kW

INDOOR

OUTDOOR

ADH series only

iZONE

CODE

SENSOR TYPE

CONNECTION

C325I v1.3

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

Single Phase - 7kw / 17kw

AD###-I

AD###-O

KADEN

CODE

SENSOR TYPE

CONNECTION

C325KAD v1.3

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

Single Phase - 7kw / 17kw

KD###

LG

CODE

SENSOR TYPE

CONNECTION

C325L v1.2

RA, Zones, Master, RF

A - B / Polarity Critical

Requires Interface board

SERIES & kW

INDOOR

OUTDOOR

B##AWYN7G5

CODE

SENSOR TYPE

CONNECTION

C325L2 v1.0

RA, Zones, Master, RF

LG Supplied connector / Polarity not Critical

SERIES & kW

INDOOR

OUTDOOR

B##AWYN7G6

MITSUBISHI ELECTRIC

CODE

SENSOR TYPE

CONNECTION

C325M2 v1.0

RA, Zones, Master, RF

A - B / Polarity not Critical

SERIES & kW

INDOOR

OUTDOOR

10kw - 14kw

PEA-M##GAA

10kw - 14kw

PEA-M##HAA

10kw - 14kw

PEA-M##JAA

16kw

PEAM160HAAYKIT

18kw

PEAM180LAAYKIT

20/25kw

PEAM200/250YKIT

MIDEA

CODE

SENSOR TYPE

CONNECTION

C325MD v1.3

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

DUC series only

MITSUBISHI HEAVY INDUSTRIES

CODE

SENSOR TYPE

CONNECTION

C325MHI v1.5

RA, Zones, Master, RF

A - B / Polarity not Critical

SERIES & kW

INDOOR

OUTDOOR

FDU Series

FDUA Series

FDUM Series

KX Series

Indoor models FDUA200VG, FDUA200VF and FDUA200VH are compatible.

PANASONIC

CODE

SENSOR TYPE

CONNECTION

C325P2 v1.5

RA, Zones, Master, RF

R1 - R2 / Polarity not Critical

SERIES & kW

INDOOR

OUTDOOR

S - series  units

Nano X high static ducted

RINNAI

CODE

SENSOR TYPE

CONNECTION

C325R v1.0

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

DINLR XX Series only

SAMSUNG

CODE

SENSOR TYPE

CONNECTION

C325S v1.3

RA, Zones, Master, RF

F3 - F4 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

R410A Gas Type - 5kW to 14Kw

AC###HBHFKH/SA

CODE

SENSOR TYPE

CONNECTION

C325SN v1.0

RA, Zones, Master, RF

F3 - F4 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

R410A Gas Type - 16kW to 20Kw

AC###JNHFKH/SA

R32 - 5kw to 14kw

AC###TNHPKG/SA

TOSHIBA

CODE

SENSOR TYPE

CONNECTION

C325T2 v1.5

RA, Zones, Master, RF

A - B / Polarity not Critical

SERIES & kW

INDOOR

OUTDOOR

 A series only / S-Net protocol

RAV-SMXXX 3DT

10kw - 16kw

RAV-GMXXXDTP-A

MMD-UP0271HP-E

TEMPERZONE

CODE

SENSOR TYPE

CONNECTION

C325TZ v1.3

RA, Zones, Master, RF

SERIES & kW

INDOOR

OUTDOOR

UC8 board or above

Not Compatible - UC7 board

YORK

CODE

SENSOR TYPE

CONNECTION

C325Y v1.3

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

6850018

6850038

6850048

UNIVERSAL

CODE

SENSOR TYPE

CONNECTION

CUCM

SERIES & kW

INDOOR

OUTDOOR