Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 92 Next »

iZone has designed interface boards for most major Air Conditioning brands. For queries about specific unit models please contact our Support Team

Phone - +61 8 6556 6415 (Press 2 for Support)

Email - supportdesk@izone.com.au

iZone is not responsible for installing units that are not listed below or for AC units manufactured before 2016. Please provide the iZone parts supplier with the model of the indoor or outdoor unit to avoid compatibility issues..

PAGE CONTENTS

ACTRON

CODE

SENSOR TYPE

CONNECTION

C325A -1.3

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

Ultra Slim \ low profile series only

LRE-###AS

URC-###AS

BRAEMAR

CODE

SENSOR TYPE

CONNECTION

C325B v1.3

RA Only

CN1 / Polarity Critical

Requires proprietary controller

SERIES & kW

INDOOR

OUTDOOR

SINGLE PHASE / 7kw - 16kw

SDHV##D1S 

SCHV##D1S 

CARRIER

CODE

SENSOR TYPE

CONNECTION

C325C v1.0

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

HIGH STATIC / 9kw - 16.5kw

42SHDV###

38SHDV###

42QSH090D8S

38QSH090D8S

42QSH105D8S

38QSH105D8S

42QSH125D8S

38QSH125D8S

42QSH140D8S

38QSH140D8S

42QSH170D8S

38QSH170D8S

DAIKIN

CODE

SENSOR TYPE

CONNECTION

C325D2 v1.2

RA, Zones, Master, RF

P1 - P2 / Polarity not critical

SERIES & kW

INDOOR

OUTDOOR

PREMIUM INVERTER SINGLE PHASE / 7kw - 16kw

FDYA###AV1

RZA###CV1

PREMIUM INVERTER SINGLE PHASE / 7kw - 16kw

FDYQ###AV1

RZQ###CV1

PREMIUM INVERTER THREE PHASE / 20kw - 25kw

FDYQ###LCV1

RZYQ##TY1

INVERTER SINGLE PHASE / 5kw - 16kw

FDYAN###AV1

RZA###CV1

INVERTER SINGLE PHASE / 5kw - 16kw

FDYQN###AV1

RZQ###CV1

INVERTER THREE PHASE / 7kw - 25kw

FDYAN###AV1

RZA###CV1

INVERTER THREE PHASE / 7kw - 25kw

FDYQN###AV1

RZQ###CV1

VRV

FXMQ###-PAVE

FDYQN250LBV1

FUJITSU

CODE

SENSOR TYPE

CONNECTION

C325F2 v1.11

RA, Zones, Master, RF

SERIES & kW

INDOOR

OUTDOOR

ARTG Series Wiring: Connect AC control cable to 2 and 3 - Polarity IS Critical

High Static Single Phase - Compact Outdoor

ARTG30LHTA

ARTG36LHTA

ARTG45LHTA

High Static Single Phase

ARTG30LHTA

ARTG36LHTA

ARTG45LHTA

ARTG54LHTC

High Static Infinity Range - Single Phase ONLY

ARTG45LDTA (single phase)

ARTG54LDTA (single phase)

ARTG60LDTA (single phase)

High Static Three Phase

ARTC72LATU

ARTC90LATU

ARTH Series Wiring: Connect AC control cable to Y2-Y3 and SW1 dip switch ON - Polarity IS Critical

only compatible with C325F2 v1.11 module

High Static Single Phase

ARTH60KHTA ( Single Phase )

Standard Range

ARTH54KHTA (Single phase)

High Efficiency

ARTH60KHTB (Single phase)

C325G - Gree R410A and New R32 Gas Type (C-S Series)

Gree are using the same model numbers for their new R32 Gas type units

CODE

SENSOR TYPE

CONNECTION

C325G v1.3

RA Only

CN1 / Polarity Critical - Requires proprietary controller

SERIES & kW

INDOOR

OUTDOOR

Single phase R410A Gas Type

GUD###PHS/B-S

GUD###W/NHB-S

R410A Gas Type models requires Gree proprietary controller for setup

SERIES & kW

INDOOR

OUTDOOR

American Design R32 Gas Type

GUD###PHS1/C-S

GUD###W1/NHC-S

C325G2 - Gree R32 Gas Type (B-S Series)

CODE

SENSOR TYPE

CONNECTION

C325G2 v1.1

RA, Zones, Master, RF

H1/H2 - Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

R32 Gas Type Only

GUD50PS/B-S

GUD50W/NHB-S

GUD71PHS/B-S

GUD71W/NHB-S

GUD100PHS/B-S

GUD100W/NHB-S

GUD125PHS/B-S

GUD125W/NHB-S

GUD140PHS/B-S

GUD140W/NHB-S

GUD160PHS/B-S

GUD160W/NHB-S

HISENSE

CODE

SENSOR TYPE

CONNECTION

Coming Soon

Coming Soon

Coming Soon

SERIES & kW

INDOOR

OUTDOOR

High Static Pressure

AUD-85UX4RSH1

AUW-85U4RK1

AUD-100UX4RSH1

AUW-100U4RK1

AUD-125UX4RSH1

AUW-125U4RH11

AUD-140UX4RSH1

AUW-140U4RH1

AUD-160UX4RSH1

AUW-160U4RH

HITACHI

CODE

SENSOR TYPE

CONNECTION

C325H v2.4

RA, Zones, Master, RF

A - B / Polarity not critical

SERIES & kW

INDOOR

OUTDOOR

R410A Gas Type

RPI ### 1SQ 

RPI ### 2SQ

R32 Gas Type

PPIM-4.0UFA1NQ

PAS-4.0UFASNQ1

PPIM-6.0UFA1NQ

PAS-6.0UFASNQ1

HAIER R410 Gas Type

CODE

SENSOR TYPE

CONNECTION

C325HI v1.3

RA Only

A - B / Polarity Critical

Requires proprietary controller / Requires Interface board

SERIES & kW

INDOOR

OUTDOOR

ADH series only

HAIER R32 Gas Type

CODE

SENSOR TYPE

CONNECTION

C325HI2 v1.0

RA, Zones, Master, RF

A-B-C / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

AD100HN5FA-SET

10kW High Static Single Phase

AD100S2SH5FA

1U100S2SN5FA

AD125HP5FA-SET

12.5kW High Static Single Phase

AD125S2SH5FA

1U125S2SP5FA

AD125HN5FA-SET

12.5kW High Static Single Phase

AD125S2SH5FA

1U125S2SP5FA

AD140HP5FA-SET

14kW High Static Single Phase

AD140S2SH5FA

1U140S2SP5FA

AD160HP5FA-SET

15.5kW High Static Single Phase

AD160S2SH5FA

1U160S2SP5FA

iZONE

CODE

SENSOR TYPE

CONNECTION

C325I v1.3

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

Single Phase - 7kw / 17kw

AD###-I

AD###-O

KADEN

CODE

SENSOR TYPE

CONNECTION

C325KAD v1.3

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

Single Phase - 7kw / 17kw

KD###

LG

CODE

SENSOR TYPE

CONNECTION

C325L v1.2

RA, Zones, Master, RF

A - B / Polarity Critical

Requires Interface board

SERIES & kW

INDOOR

OUTDOOR

B##AWYN7G5

CODE

SENSOR TYPE

CONNECTION

C325L2 v1.0

RA, Zones, Master, RF

LG Supplied connector / Polarity not Critical

SERIES & kW

INDOOR

OUTDOOR

B##AWYN7G6

MITSUBISHI ELECTRIC

CODE

SENSOR TYPE

CONNECTION

C325M2 v1.0

RA, Zones, Master, RF

A - B / Polarity not Critical

SERIES & kW

INDOOR

OUTDOOR

10kw - 14kw

PEA-M##GAA

10kw - 14kw

PEA-M##HAA

10kw - 14kw

PEA-M##JAA

16kw

PEAM160HAAYKIT

18kw

PEAM180LAAYKIT

20/25kw

PEAM200/250YKIT

PEAM200LAA-TH

Below units (R410A Gas Type) are NOT compatible with M2 module and requires C325M. Please contact our sales team on salesdesk@izone.com.au if you need one of C325M modules.

PEA-RP200WJA

PUZ-RP200YKA

PEA-RP250WHA

PUZ-RP250YKM

MIDEA

CODE

SENSOR TYPE

CONNECTION

C325MD v1.3

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

DUC series only

MITSUBISHI HEAVY INDUSTRIES

CODE

SENSOR TYPE

CONNECTION

C325MHI2 v1.5

RA, Zones, Master, RF

A - B / Polarity not Critical

SERIES & kW

INDOOR

OUTDOOR

FDU Series

FDUA Series

FDUM Series

KX Series

Indoor models FDUA200VG, FDUA200VF and FDUA200VH are compatible.

PANASONIC

CODE

SENSOR TYPE

CONNECTION

C325P2 v1.5

RA, Zones, Master, RF

R1 - R2 / Polarity not Critical

SERIES & kW

INDOOR

OUTDOOR

S - series  units

Nano X high static ducted

RINNAI

CODE

SENSOR TYPE

CONNECTION

C325R v1.0

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

DINLR XX Series only

SAMSUNG

CODE

SENSOR TYPE

CONNECTION

C325S v1.3

RA, Zones, Master, RF

F3 - F4 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

R410A Gas Type - 5kW to 14Kw

AC###HBHFKH/SA

CODE

SENSOR TYPE

CONNECTION

C325SN v1.0

RA, Zones, Master, RF

F3 - F4 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

R410A Gas Type - 16kW to 20Kw

AC###JNHFKH/SA

R32 - 5kw to 16kw

AC###TNHPKG/SA

TOSHIBA

CODE

SENSOR TYPE

CONNECTION

C325T2 v1.5

RA, Zones, Master, RF

A - B / Polarity not Critical

SERIES & kW

INDOOR

OUTDOOR

 A series only / S-Net protocol

RAV-SMXXX 3DT

10kw - 14kw

RAV-GMXXXDTP-A

MMD-UP0271HP-E

TEMPERZONE

CODE

SENSOR TYPE

CONNECTION

C325TZ v1.3

RA, Zones, Master, RF

SERIES & kW

INDOOR

OUTDOOR

UC8 board or above

Not Compatible - UC7 board

YORK

CODE

SENSOR TYPE

CONNECTION

C325Y v1.3

RA, Zones, Master, RF

CN40 / Polarity Critical

SERIES & kW

INDOOR

OUTDOOR

6850018

6850038

6850048

UNIVERSAL

CODE

SENSOR TYPE

CONNECTION

CUCM

SERIES & kW

INDOOR

OUTDOOR

  • No labels